533
[II] Target Tracking Simulator
Pseudo targets can be generated in certain known positions to check whether the TT processing circuits are
operating normally. Since the pseudo targets move depending on known parameters, the values for these
pseudo targets can be compared with the known value if the pseudo targets are acquired and tracked, and
displayed. Thus, it can be checked if the TT system is operating normally.
Procedure
1 Press the [STBY] key.
The equipment will enter the standby state.
2
Press [TT MENU] key.
Press [6] key.
The TT Test Menu will appear.
3
Press [2] key.
Choices for the TT simulator (TT Simulator) are
displayed.
4
Select the simulator to be set, pressing
the numeric key.
The selected simulator will be set.
5
Press the [TX/PRF] key.
The simulator will be activated and generate pseudo targets. The characters "X" at the
bottom of the radar display blinks indicating that the simulation mode is active.
TT simulator/scenario
TARGET START POINT
TARGET END POINT
SCENARIO
DISTANCE
BEARING
DISTANCE
BEARING
TARGET SPEED
1 3.2NM
10
q
1NM
90
q
20kts
2 6NM
0
q
0NM
0
q
10kts
3 6NM
every 18
q
1NM
every 18
q
10kts
4 6NM
45
q
1NM
45
q
105kts
5 6NM
45
q
6NM
150
q
20kts
6 6NM
45
q
6NM
150
q
20kts
Note:
Set the ship's heading bearing to 0º and the own ship speed to 0 kn while the simulator is operating.
When the range between own ship and the pseudo target is 0, the target will disappear.
Summary of Contents for JMA-5212-4
Page 2: ......
Page 18: ... xii NKE 2103 6 6HS Scanner Unit NKE 2254 7 9 6HS Scanner Unit Warning Label Warning Label ...
Page 19: ... xiii ...
Page 38: ... xxxii ...
Page 45: ...1 4 EXTERIOR DRAWINGS 1 6 1 y Fig 1 1 Exterior Drawing of Scanner Unit Type NKE 2103 4 ...
Page 46: ...1 7 Fig 1 2 Exterior Drawing of Scanner Unit Type NKE 2103 6 ...
Page 47: ...1 4 EXTERIOR DRAWINGS 1 8 1 y Fig 1 3 Exterior Drawing of Scanner Unit Type NKE 2254 7 ...
Page 48: ...1 9 Fig 1 4 Exterior Drawing of Scanner Unit Type NKE 2254 9 ...
Page 49: ...1 4 EXTERIOR DRAWINGS 1 10 1 y Fig 1 5 Exterior Drawing of Monitor Unit Type NWZ 164 ...
Page 50: ...1 11 Fig 1 6 Exterior Drawing of Processor Unit Type NDC 1460 ...
Page 51: ...1 4 EXTERIOR DRAWINGS 1 12 1 y Fig 1 7 Exterior Drawing of Keyboard Unit Type NCE 7699A ...
Page 52: ...1 13 Fig 1 8 Exterior Drawing of NSK Unit Type NCT 4106A ...
Page 56: ...1 17 ...
Page 58: ...2 1 2 1 EXAMPLE OF DISPLAY ...
Page 78: ...2 21 ...
Page 234: ...3 155 ...
Page 316: ...5 75 ...
Page 332: ...6 15 ...
Page 358: ...7 25 Exit 1 Press RADAR MENU key The Main Menu will reappear ...
Page 434: ...8 39 ...
Page 452: ...10 5 ...
Page 477: ...Figure 8 NKE 2254 Interconnection Diagram of Scanner Unit ...
Page 493: ......