Method of setting and explanation of the each items on X-BUS MODE A.
፧
ID : There are two ID's - one is the Main ID and the second is the Sub ID. The Main ID configures channel
numbers. The Sub ID configures up to a maximum of 4 servos, data which can be adjusted individually.
፧
ID Change ( ID CHANGE)
It is possible to adjust X-BUS devices through the Transmitter. Input both the ID from X-BUS device andthe
desired ID. Place the Cursor on “SET” and press the dial to finalize the setting.
፧
ID Reset (ID RESET)
It is possible to reset X-BUS devices to their initial settings through the Transmitter. Set the Cursor to “ID
CHANGE” and press the dial to finalize. “ID CHANGE” will be highlighted in reverse text. Place the Cursor on
“SET” and press the dial to finalize the ID RESET.
፧
Reverse (REVERSE)
It is possible to reverse the servo direction. Set the particular servo’s Channel ID and Sub ID, Set either
Normal or Reverse and Press the dial. Place the Cursor on “SET” and press the dial to finalize.
፧
Neutral (NEUTRAL)
It is possible to set the servo neutral. Set the particular servo’s Channel ID and Sub ID, Set the cursor on “+”or “
- ” to change the neutral value, Place the Cursor on “SET” and press the dial to finalize.
፧
Travel(TRAVEL)
It is possible to set the servo travel. Set the particular servo’s Channel ID and Sub ID, Set the cursor on “+” or “
- ” to change the travel value, Place the Cursor on “SET” and press the dial to finalize.
※ These setting must be accomplish with Transmitter and Receiver being bound (paired) together and X-BUS
devices must be appropriately connected with power turned on.
Note:
Be sure to remove the bind plug from the receiver bind port, otherwise setting cannot be accomplished.
▋
▋
Caution▋Items
▋
Actually operate the servos and carefully confirm the setting before flying.
Main ID on Left and Sub ID on
Right for compliant Device
which need to change ID.
Main ID on Left and Sub ID on
Right for compliant Device.
Set the Cursor on the specific
item and Press the scroll dial
to finalize.
This is the value of the SETTING amount that
determines how precisely the servo moves for one
increment of increase-decrease. (similar to trim
step) It can be set between 1% - 10% with 1%
offering fine control and 10% coarse adjustment.
Press either “+” or “- to increase
or decrease the numerical value
on setting value in the center.