67
Modul-AIR Exhaust Air Heat Pump Installation Guide
Modul-AIR Tank
The All-E and Aqua versions of the Modul-AIR Exhaust Air Heat Pump system is supplied with a purpose-
built Modul-AIR indirect Hot Water Tank. The Tank is designed from the ground up to work in tandem with
the Modul-AIR unit specifically. The Tank is provided with a 2kW backup water heating immersion that can
work in conjunction the Modul-AIR unit to speed up how water recovery times, in certain hot water modes.
An unvented kit is also provided with the tank allowing the hot water system to be pressured to a working
pressure of 3 Bar.
* - Heat up time is based on the EN12897 standard and the Heat Pump reheat time may differ.
** - Heat loss is based on the EN12897 standard.
Modul-AIR Indirect Tank Specs
Item No
TUMA-00150-LFC
TUMA-00180-LFC
TUMA-00210-LFC
Capacity
150L
180L
210L
Internal Tank Material
Stainless Steel - Duplex LDX 2101
Thermal Insulation
Polyurethane foam CFC-Free & HCFC Free
Casing
Painted Galvanised Carbon Steel DX51D
Coil Material
Stainless Steel Tube AISI 316L
Weight (empty) kg
38
42
45
Weight (full) kg
185
218
248
Max. Operating Pressure
5 (bar)
Test Pressure
10 (bar)
Max. Working Temperature
90
o
C
Heating Elements
1. No. 2kW Incoloy Immersion
Heat Loss
53
58
62
Heat up Time (mins)*
24
29
33
Energy Efficiency Class**
C
Height (mm) “A”
1102
1293
1478
Diameter (mm) “B”
545
Plan View
Left Side View
Front View
Right Side View
B
A
B
Summary of Contents for HHH-AEHP-00001
Page 32: ...32 www jouleuk co uk www joule ie Modul AIR Concrete Block Wall Build up 1 3 4 6 8 5 2 7...
Page 36: ...36 www jouleuk co uk www joule ie Modul AIR Timber Stud Build up 1 4 8 7 2 5 6 3...
Page 71: ...71 Modul AIR Exhaust Air Heat Pump Installation Guide Modul AIR Unit Menu Overview...
Page 72: ...72 www jouleuk co uk www joule ie...
Page 115: ...115 Modul AIR Exhaust Air Heat Pump Installation Guide...