68
www.jouleuk.co.uk | www.joule.ie
N.B
If an appliance capable of heating the tank above 89°C is connected to the primary coil then, a separate
non-self-resetting thermostat and 2 port valve must be installed in the primary circuit
For further details on the Modul-AIR Tank and for detailed installation instructions regarding Indirect
unvented tanks please consult the Direct, Indirect, Slimline & Modul-AIR Un-Plumbed Unvented Cylinder
Installation & Maintenance Manual (INS-JUKCYL-020).
Reference
Description
Connection Size
A
Hot water Outlet
22mm compression connection
B
Overheat Stat
22mm Pocket
C
T&P Relief Valve
½” Female BSP
D
Top Tank Sensor
ID Ø7mm Stat Pocket
E
2kW Immersion Heater
1 ¾” Female BSP
F
Bottom Tank Sensor
ID Ø7mm Stat Pocket
G
Coil Flow/Return
22mm compression connection
H
Coil Flow/Return
22mm compression connection
I
Cold Water Inlet
22mm compression connection
A
B
C
D
E
F
G
H
J