56
www.jouleuk.co.uk | www.joule.ie
Power Specification
Modul-AIR Electrical Connections
Unit
HZ
Volts
Phase
Starting Current
Mains Fuse
Joule Modul-AIR Aqua
50
230
Single
10 Amp
16 Amp
Joule Modul-AIR All-E
50
230
Single
10 Amp
32 Amp
Green Comfort
50
230
Single
10 Amp
16 Amp
Modul-AIR - Cable Specifications
Unit Mains Power
3 Core Flex, 6mm2, 1 meter Fly Lead
x1
Supplied
Tank Sensor
2 Core, 0.25-0.50mm2, 2 meter
x2
Supplied
Immersion Power
3 Core, 1.5mm2
x1
Not supplied
Room Thermostats
2 Core, 0.75mm2 OT
x1
Not supplied
RF Receiver (Optional)
3 Core, 0.5mm2
x2
Not supplied
Green Comfort - Cable Specifications
Unit Mains Power
3 Core Flex, 6mm2, 1 meter Fly Lead
x1
Supplied
UTP Comms cable
UTP Data cable, 3 meter
x1
Supplied
•
The Heat Pump MUST be connected to the mains through a suitably sized RCBO.
•
The power cable is pre-wired to the Exhaust Air Heat Pump.
•
This Equipment complies with IEC 61000-3-12.
•
If extension of the power cable is required, use the grade H05V2V2-F or equivalent materials.
•
Ensure that main supply connection is made through a switch that disconnects all poles, with contact
gap of a least 3 mm.
•
Devices disconnected from the power supply should be completely disconnected in the condition of
overvoltage category.
•
Keep distances of 20mm or more between power cable and communication cables.
During the unit installation first install the ventilation connections, then the piping
connections and then finally the electrical connections.
If the unit is being uninstalled disconnect it in a reverse procedure to the above
Summary of Contents for HHH-AEHP-00001
Page 32: ...32 www jouleuk co uk www joule ie Modul AIR Concrete Block Wall Build up 1 3 4 6 8 5 2 7...
Page 36: ...36 www jouleuk co uk www joule ie Modul AIR Timber Stud Build up 1 4 8 7 2 5 6 3...
Page 71: ...71 Modul AIR Exhaust Air Heat Pump Installation Guide Modul AIR Unit Menu Overview...
Page 72: ...72 www jouleuk co uk www joule ie...