30
www.jouleuk.co.uk | www.joule.ie
45mm
45mm
110mm
Mounting the Green Comfort
The mounting method for the Green Comfort Module is very similar to that of the Modul-AIR. The
recommended and preferred method for mounting the Green Comfort unit would be directly hung on a
wall using the wall bracket supplied. If the wall is not capable of holding the weight of both the Modul-AIR
and Green Comfort units, details of how to build the wall up appropriately are shown in the next Wall Build
Up section below.
There are no other mounting options that will comply with Joules manufacturing and supply warranty, any
possible attempt to do so would void Joules statutory responsibilities.
Wall Mounting
Increase weight for the wall to be capable
of holding to 225kg/m
2
for Modul-AIR and
GC. If the wall mass is lower than this, ensure
the recommended wall build-up is adhered
to. The Green Comfort should always be
hung level however there is a permitted
tolerance of 2°. If there are any concerns
relating to the correct wall build-up, please
contact joule directly before installation.
1.
Measure and mark positions for
pilot holes based on the dimensions
displayed here.
2. Mount the wall bracket using the
supplied screws and plugs or suitable
alternatives.
3. Hang the Green Comfort on the wall
bracket. Ensure the tab protrudes from
the top of the unit, this is evidence the
unit has engaged the bracket fully.
min.
920mm
670mm
30mm
700mm
Summary of Contents for HHH-AEHP-00001
Page 32: ...32 www jouleuk co uk www joule ie Modul AIR Concrete Block Wall Build up 1 3 4 6 8 5 2 7...
Page 36: ...36 www jouleuk co uk www joule ie Modul AIR Timber Stud Build up 1 4 8 7 2 5 6 3...
Page 71: ...71 Modul AIR Exhaust Air Heat Pump Installation Guide Modul AIR Unit Menu Overview...
Page 72: ...72 www jouleuk co uk www joule ie...