Modul-AIR & Green Comfort - Technical Specifications:
SPECIFICATIONS
UNIT
CONFIGURATION
SOLO
AQUA
ALL-E
Green Comfort
Mains connection
P+N230V
~50Hz
+10%-6%”
P+N230V
~50Hz
+10%-6%”
P+N230V
~50Hz
+10%-6%”
P+N230V
~50Hz
+10%-6%”
Fuse
a
32
16
32
16
Max. power consumption
W
620
620
6370
80
Max. absorbed electrical
power heat pump
W
620
620
620
N/A
Max. power consumption
instantaneous
W
N/A
N/A
3450
N/A
Max. absorbed power excl.
DHW Tank element
W
N/A
N/A
2300
N/A
Average electrical consumption
power heat pump
W
300
300
300
N/A
IP Class
X2
X2
X2
X2
Max. working pressure
kPa
300
300
300
300
Cord type
3 core cable
flex (1m)
3 core cable
flex (1m)
3 core cable
flex (1m)
3 core cable
flex (1m)
PERFORMANCE
Max. supply temperature
C
60
60
60
65
Max. delivered thermal power
kWh
1.71
1.71
1.71
3.5
COP (20 °C-45 °C)
5.0
5.0
5.0
N/A
Reheater power
kW
N/A
N/A
max 4.5 kW
+ 15%
N/A
REFRIGERANT
Refrigerant
Type
R134a
R134a
R134a
N/A
Refrigerant content
g
580
580
580
N/A
GWP Value
1430
1430
1430
N/A
C02 equivalent
kg
830
830
830
N/A
DIMENSIONS AND WEIGHT
Height
mm
700
700
700
700
Width
mm
500
500
500
298
Depth
mm
500
500
500
493
Weight
kg
58
55
60
20
Summary of Contents for HHH-AEHP-00001
Page 32: ...32 www jouleuk co uk www joule ie Modul AIR Concrete Block Wall Build up 1 3 4 6 8 5 2 7...
Page 36: ...36 www jouleuk co uk www joule ie Modul AIR Timber Stud Build up 1 4 8 7 2 5 6 3...
Page 71: ...71 Modul AIR Exhaust Air Heat Pump Installation Guide Modul AIR Unit Menu Overview...
Page 72: ...72 www jouleuk co uk www joule ie...
Page 115: ...115 Modul AIR Exhaust Air Heat Pump Installation Guide...