111
Modul-AIR Exhaust Air Heat Pump Installation Guide
Additional Mechanical Schematic
Modul-AIR All-E & Green Comfort - 1 DHW & 1 Underfloor Zone
Kit
chen
Bathroom
Ensuite
Utilit
y
G
H
B
C
J
L
K
A
E2
I
D
E1
F
Duct
entry
/
e
xit
grilles
should
be
separated
b
y
a
minimum
distance of 3 meters
M
N
Descriptio
n
A
Modul-AIR Hot Water Tank
B
Modul-AIR Heat Pump
C
Tundish
D
Green Comfort Module
E1
Potable Expansion
Ve
ssel
E2
Heating Expansion
Ve
ssel
F
Opentherm thermostat
G
Fill & Flush V
alv
e
H
I
Filterball
J
Hot O
utlet
K
B
alanced Cold O
utlet
L
M
N
M
ains/Boosted Cold Inlet
Pressure Relief Valve
D
Inlet Control Group
MVHR
V
entilation