27
JO
NIX
mate
07
08
09
10
Fig. 07: Gently unscrew the tubes, using
the green plastic base. If you have trouble,
first pull off the outer mesh.
Fig. 08: Pull off the outer mesh from the
tube if you have not already done so in the
previous point.
If this is difficult to do, turn the mesh around
the glass while pulling to remove it.
Fig. 09: Clean the glass using a damp
cloth.
Do not use liquid cleaners or
sprays, soap or the like.
Check that the tube is in good conditions: there must not be any cracks or other damage;
otherwise it must be replaced. As soon as you notice a whitish layer on the perforated
metal plate inside the glass it means that the ionising tube needs replacing.
The tubes must usually be replaced within 18 months of use.
Fig. 10: Wash the mesh under running hot
water and dry it thoroughly with a cloth.
Do not put back the mesh on
the ionising tube if it is even
partially wet.
If the operation is difficult
to perform, pull slightly the
earthing spring so that it is not
in contact with the surface of
the tube.