The components of the device subject to time deterioration hence they need to be replaced are:
- ionising tubes: when signs of wear appear, it is necessary to replace the component. They are
evident with the appearance of oxide in the condenser internal mesh that will make it whitish,
and that will render the glass opaque. The device will signal the need of replacement of the
component after 14000 hours of operation.
- filters: the components have the function of barrier, and they tend to saturate so that eventually
they will obstruct the air flow. The detection devices internal to
JO
NIX
mate
signal how
necessary is an operation of replacement in order to maintain a smooth functioning of the
device.
8.3 SPECIAL MAINTENANCE
8.3.1 Replacing the ionising tubes
Replace the ionising tubes every time it is notified on the display.
Fig.17: Switch the device off by turning
the luminous On/Off switch to O.
Remove the plug connected to the mains.
Fig. 18: Use a screwdriver to open the rear
panel.
Fig. 19: Switch the
JO
NIX
duct
module
off by turning the luminous On/Off switch to
O.
Disconnect the power supply plug and the
other plugs from the
JO
NIX
duct
module.