21
johnson controls
ForM 102.20-n1 (1109)
Unit ID Label
The Unit ID Label contains the Model number, Serial/
Date Code, Job Identification number, Segment
Identification, the number of Skids, Unit Tag number,
Electrical Ratings, Coil Data and Manufacturing
Location (see Fig. 3).
Skid ID Label
Each skid in a multi piece unit is marked with a Skid
ID Label, which indicates its order of assembly in the
direction of airflow
(see Fig. 4).
Segment Identification Box
The Segment Identification box indicates the skids and
segments* used on a multi piece unit. The contents of
each skid are indicated by segment(s) surrounded by
parenthesis
(see Fig. 5 below).
FIG. 3 – UNIT ID LABEL
lD11728A
THIS PRODUCT MANUFACTURED FOR
USE
UNIT ID.
MODEL #
SERIAL # / DATE CODE
JOB IDENTIFICATION #
SEGMENT IDENTIFICATION
# OF SKIDS
UNIT TAG #
YORK INTERNATIONAL -
FACILITY
MANUFACTURING LOCATION
ELECTRICAL RATINGS
COIL DATA
TOTAL RATINGS (COMBINED LOADS)
VOLTS / PH / HZ
M.C.A.
MAX. O.C. PROT.
SUPPLY FAN MOTOR RATING (INDIVIDUAL LOAD)
HP
FLA
M.C.A.
MAX. O.C. PROT.
RETURN FAN MOTOR RATING (INDIVIDUAL LOAD)
HP
FLA
M.C.A.
MAX. O.C. PROT.
HEAT RECOVERY WHEEL MOTOR RATING (INDIVIDUAL LOAD)
HP
FLA
M.C.A.
MAX. O.C. PROT.
LIGHTS & OUTLETS
VOLTS / PH / HZ
M.C.A.
MAX. O.C. PROT.
HOT WATER COIL MAX. INLET WATER TEMP.
STEAM COIL MAX. OPERATING PRESSURE.
EVAPORATOR COIL DESIGN PRESSURE.
EVAPORATOR COIL REFRIGERANT USED.
EVAPORATOR COIL REFRIGERANT OIL USED.
SUITABLE FOR USE WITH REMOTE CONDENSER; AIR-COOLED, WATER-COOLED, OR
VAPORATIVE. THE DESIGN PRESSURE MARKED ABOVE SHALL NOT BE LESS THAN THE
DESIGN PRESSURE MARKED ON THE REMOTE CONDENSING UNIT.
XTO-108X120-JJRN046A
CHTM XT0085
08-179121-01-01
(FS)(CC-HM)(XA-IC-XA-RF)(EE)(FR)
5
AHU 9-10
460/3/60
_____
_____
50
72
90
150
25
38
47.5
80
N/A
N/A
N/A
N/A
120/1/60
20
20
200 F
50
325 PSI
_____
_____
East York
1499 E PHILADELPHIA ST
YORK
PA
17403
OUTDOOR
117817
COM :
ELECTRIC HEAT RATINGS
GAS HEAT RATINGS
9800071
N/A
N/A
USE COPPER WIRES ONLY. CLEARANCE FROM COMBUSTIBLE SURFACE: UNIT IS 0 INCHES,
DUCT IS 0 INCHES. MAXIMUM INLET TEMPERATURE; 100^ F / MAXIMUM OUTLET
TEMPERATURE; 200^ F. EXTERNAL STATIC PRESSURE RANGE OF 0.25'' - 5.00'' WG. CONFORMS
TO UL STD 1995 AND CERTIFIED TO CSA STD C22.2 NO 236
See Fig. 5 for
Segment ID
explanation
lD11752A
(Skid 5 of 5)
(Skid 1 of 5)
(Skid 2 of 5)
(Skid 4 of 5)
(Skid 3 of 5)
(FS)(CC-HM)(XA-IC-XA-RF)(EE)
(FR)
Direction of Airflow
Order of Assembly
* See Table 1 for Segment Identification
FIG. 5 – SEGMENT ID BOX EXAMPLE
FIG. 4 – SKID ID LABEL
(FR)
Bolded indicates skid 1 of 5 is a return
Fan and is placed first in the direction of airflow.
see segment ID box example.
lD11729A
4,100
MODEL #
SERIAL # / DATE CODE
JOB IDENTIFICATION #
SEGMENT IDENTIFICATION
SKID
JOB NAME
XTO-108X120-JJRN046A
CHTM XT0085
08-179121-01-01
(FS)(CC-HM)(XA-IC-XA-RF)(EE)
(FR)
1
5
of
117817
COM :
AHU 9-10
Owens Corning BLDG-21
116 H x 120 W x 59 L
SKID OVERALL SIZE
AHU 9-10
UNIT TAG
Estimated Weight:
pounds
Unit Identification
Both indoor and outdoor units are labeled with a Unit
ID Label, Skid ID Labels and Loose Component ID
Labels. Indoor units are shrink wrapped with Skid ID
Labels on the outside of the wrapping as well as on
each skid.
Summary of Contents for YORK SOLUTION LD09624
Page 4: ...johnson controls 4 FORM 102 20 N1 1109 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 10: ...johnson controls 10 FORM 102 20 N1 1109 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 16: ...johnson controls 16 FORM 102 20 N1 1109 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 30: ...johnson controls 1 8 FORM 102 20 N1 1109 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 106: ...johnson controls 2 76 FORM 102 20 N1 1109 THIS PAGE INTENTIONALLY LEFT BLANK ...