76
Expandable Hybrid Control Panel
EVENTS
OCCURS WHEN...
ENDS WHEN...
Autoarming
Warning on
Panel
... an Auto-Arm Timeout starts.
... ALL Partition Arm or an Overtime Request is
made.
Memory Alarm
on Panel
... a Generic alarm on partition Event occurs.
... ALL Partition Reset.
Alarm Stop on
Panel
... a Stop Alarm request is made.
... the Control panel exits the Stop Alarms Sta-
tus.
Valid Key on
Panel
... a valid Key is used on a Reader.
... ALL the Keys are removed from the Read-
ers.
Valid Code on
Panel
... arming, special arming, disarming or
ENTER
key is pressed after entry of a VALID User PIN.
SPOT EVENT!
Valid Keyfob on
Panel
... one of the
Valid Keyfob
events occurs (see
SPOT EVENT!
False Key on
Panel
... a false Key is used on a Reader.
... ALL false Keys have been withdrawn from
the Readers.
Invalid Code on
Panel
... arming, special arming, disarming or
ENTER
key is pressed after entry of an INVALID User
PIN.
SPOT EVENT!
Super Key 1 on
Panel
... the key
1
on a LCD Keypad (the Key
on a
Touch Keypad) is pressed e hold for 3 (2) sec-
onds.
SPOT EVENT!
Super Key 2 on
Panel
... the key
2
on a LCD Keypad (the Key
on a
Touch Keypad) is pressed e hold for 3 (2) sec-
onds.
SPOT EVENT!
Super Key 3 on
Panel
... the key
3
on a LCD Keypad (the Key
on a
Touch Keypad) is pressed e hold for 3 (2) sec-
onds.
SPOT EVENT!
Keyfob Super
Key on Panel
... one of the
Super Key on Keyfob
events occurs
SPOT EVENT!
Surveillance
Maintenance on
Panel
... the control Panel clock reaches the time and
date scheduled for the maintenance of the Se-
curity Service.
SPOT EVENT!
Arm Refused on
Panel
... a request of Arming was refused due to block
condition.
SPOT EVENT!
Panel Fault
... a fault happens on the control panel.
... the last fault on the control panel restores.
System Fault
... a fault happens on the system.
... the last fault on the system restores.
Zone
Fault/Masking
... one of the
Zone Fault/Masking
events occurs
... ALL the
Zone Fault/Masking
events end (see
Automatic
Arming Refused
... during auto-arming, a zone is on alarm. At
default, the Panel must inhibit the arming with-
out activating the alarm.
SPOT EVENT!
Tamper on
Armed System
... an Armed Partition's Zone is tampered.
... ALL the Armed Partition's Tampered Zones
return to standby status.
GSM Absence
... the
Present
and
Enabled
options in the
GSM
options group are ENABLED (and the
control panel has been UNABLE to communi-
cate with the GSM Module for 30 seconds).
... the
Present
and
Enabled
options in the
GSM
options group are ENABLED and the
control panel succeeds in communicating with
the GSM Module.
GSM Link Lost -
General
... the GSM network is busy, there is no GSM
signal, or there is a problem with the SIM card.
... the GSM network is free, GSM signal is pres-
ent, and the GSM Module is communicating
using the SIM card.
GSM Link Lost -
Jamming/DoS
... the options
Present
and
Enabled
of the
GSM
option group are ENABLED, the option
Cellular Jamming/DoS Generates Fault
of the
group
System Options
>
EN50131/EN50136
is
ENABLED and the GSM Module detects a DoS
or jamming attack.
... the options
Present
and
Enabled
of the
GSM
option group are ENABLED, the option
Cellular
Jamming/DoS Generates Fault
of the group
System Options
>
EN50131/EN50136
is
ENABLED and the GSM Module does NOT de-
tect any DoS or jamming attack.
Table 14
System Events (continued on next page).