ABSOLUTA Plus
PROGRAMMING FROM THE PC
77
EVENTS
OCCURS WHEN...
ENDS WHEN...
GSM Receiver 1
LOST
... the
Present
and
Enabled
options and, those
relating to Receiver
1
in the GSM options group
are ENABLED, and the GSM module has prob-
lems communicating with the receiver
1
.
... the
Present
and
Enabled
options and, those
relating to Receiver
1
in the GSM options group
are ENABLED, and the GSM module is able to
communicate with the receiver
1
.
GSM Receiver 2
LOST
... the
Present
and
Enabled
options and, those
relating to Receiver
2
in the GSM options group
are ENABLED, and the GSM module has prob-
lems communicating with the receiver
2
.
... the
Present
and
Enabled
options and, those
relating to Receiver
2
in the GSM options group
are ENABLED, and the GSM module is able to
communicate with the receiver
2
.
GSM - Cellular
Network Fault
... the
Present
and
Enabled
options in the
GSM
options group are ENABLED and the
GSM module has problems communicating
with the GSM network.
... the
Present
and
Enabled
options in the
GSM
options group are ENABLED and the
GSM module is able to communicate with the
GSM network.
Arming refused
on command
zones
... an arming request via a command zone has
been refused due to block conditions.
SPOT EVENT!
Arming refused
on keyfob
... an arming request via keyfob has been re-
fused due to block conditions.
SPOT EVENT!
Duplicated and
Discovered PIN
... the
Auto PIN Generation
option is disabled,
the
Disable code if duplicated PIN
option is
ENABLED (see
System Options
>
General
options group) and a user programs a PIN
used by another user.
SPOT EVENT!
User request
service
... the user requests the Remote Service from a
Keypad (see the USER MANUAL).
SPOT EVENT!
IP absence
.. .the
Present
and
Enabled
options in the
IP
options group are ENABLED and the control
panel has been UNABLE to communicate with
the IP Module for 30 seconds.
... the
Present
and
Enabled
options in the
IP
option group are ENABLED and the control
panel succeeds in communicating with the IP
Module.
IP link lost -
General
... the
Present
and
Enabled
options in the
IP
options group are ENABLED and the IP Mod-
ule does NOT see the LAN network.
... the
Present
and
Enabled
options in the
IP
option group are ENABLED and the IP Module
sees the LAN network.
IP Link Lost -
DoS
... the options
Present
and b of the
IP
option
group are ENABLED, the option
IP DOS Gen-
erates Fault
of the group
System Options
>
EN50131/EN50136
is ENABLED and the IP
Module detects a DoS attack.
... the options
Present
and
Enabled
of the
IP
option group are ENABLED, the option
IP DOS
Generates Fault
of the group
System Options
>
EN50131/EN50136
is ENABLED and the IP
Module does NOT detect any DoS attack.
IP remote lost
... the
Present
,
Enabled
and
Absoluta Server
options in the
IP
options group are ENABLED
and the IP Module is NOT able to communicate
with the remote server.
... the
Present
,
Enabled
and
Absoluta Server
options in the
IP
options group are ENABLED
and the IP Module is ABLE to communicate
with the remote server.
IP receiver 1
lost
... the
Present
and
Enabled
options and, those
relating to Receiver
1
in the
IP
options group
are ENABLED, and the IP module has prob-
lems communicating with the receiver
1
.
... the
Present
and
Enabled
options and, those
relating to Receiver
1
in the
IP
options group
are ENABLED, and the IP module is able to
communicate with the receiver
1
.
IP receiver 2
lost
... the
Present
and
Enabled
options and, those
relating to Receiver
2
in the
IP
options group
are ENABLED, and the IP module has prob-
lems communicating with the receiver
2
.
... the
Present
and
Enabled
options and, those
relating to Receiver
2
in the
IP
options group
are ENABLED, and the IP module is able to
communicate with the receiver
2
.
Loss of Time
Trouble
... the panel is powered.
... the date and time are adjusted.
Low Voltage on
Main Power*
... the output voltage of A Power Station is less
than 10.6 V.
... the output voltage of ALL the Power Stations
is greater than 10.6 V.
Low Voltage on
Output 1*
... the output voltage of
O1
output of A Power
Station is less than 10.6 V.
... the output voltage of
O1
output of ALL Power
Stations is greater than 10.6 V.
Low Voltage on
Output 2*
... the output voltage of
O2
output of A Power
Station is less than 10.6 V.
... the output voltage of
O2
output of ALL Power
Stations is greater than 10.6 V.
Low Voltage on
Output 3*
... the output voltage of
O3
output of A Power
Station is less than 10.6 V.
... the output voltage of
O3
output of ALL Power
Stations is greater than 10.6 V.
Table 14
System Events:
*)
this event is ONLY available on Grade 3 Control Panels and Grade 3 Power Stations.