is violated along with another zone of the same partition
that has the same option enabled within the
Time-In
AND zones time
of the partition to which the zones be-
long (see “Partitions”).
Default:
disabled.
Any time a Partition is armed its
Time-In AND zones
time
is reset to zero.
If any zone with this option enabled, is violated while the
Time-In AND zones time
is NOT running:
Ø
the Partition
Time-In AND zones time
starts;
Ø
the Partition alarm is NOT generated;
Ø
the zone alarm is NOT logged;
Ø
the zone which started the
Time-In AND zones time
is stored.
If the same zone is violated again while the
Time-In AND
zones time
is running:
Ø
the zone alarm is NOT logged;
Ø
the
Time-In AND zones time
is restarted.
If another Partition Zone with this option enabled, is vio-
lated while the
Time-In AND zones time
is running:
Ø
the zone alarm is logged;
Ø
the Partition alarm is generated;
Ø
the
Time-In AND zones time
restarts again.
If the
Time-In AND zones time
expires:
Ø
the
AND zone timeout
event is logged.
Options-Real Time
If this option is disabled (default),
the zone alarm event ends when the system alarm time
expires.
If this option is enabled, the zone alarm event ends
when the zone goes back to standby status.
Options-Active On Keypads
If this option is enabled,
the zone activation generates a message on the keypads
associated to the partitions the zone is assigned to.
+
The message is displayed ONLY on keypads with
option
EN50131
disabled.
Options-Check Inactivity
If this option is enabled, the
control panel check the inactivity on the zone.
+
For more information, refer to the
Inactivity
option
in the
Partitions
option group.
Partitions
This option will allow you to assign the
Alarm and Command Zones to the Partitions.
Ø
For Alarm Zones
, will determine which User PINs,
Keys and Operating Times will be associated with the
Zone. Each Alarm Zone can be assigned to more than
one Partition.
+
If the Zone is a Delayed Zone (Entry Delay, Path,
Exit Delay or Last Exit Delay), the system will apply
the longest Entry Delay, Exit Delay or Last Exit De-
lay of all its Armed Partitions.
Ø
For Command Zones
, will determine which Parti-
tions the Zone will be able to control. Each Com-
mand Zone can operate on more than one Partition.
52
Expandable Hybrid Control Panel