78
Expandable Hybrid Control Panel
EVENTS
OCCURS WHEN...
ENDS WHEN...
Dialler Action
Failed on
Telephone
... a call, in Dialler mode, to the phone number
failed.
SPOT EVENT!
Timer Event
... the timer switches ON.
... the timer switches OFF.
Table 15
Other Events.
Remote
Command
... the control panel receives the following SMS:
#ABS#E#<PIN>#ON#<Command String>#<Text>
(see "Remote Command Events") or the appro-
priate command from the
ABSOLUTA
App or
from an
ABSOLUTA M-Touch
keypad (see
"USER MANUAL > Touch Keypad Operations
> Scenarios").
... the control panel receives the following SMS:
#ABS#E#<PIN>#OFF#<Command String>#<Text>
(see "Remote Command Events") or the appro-
priate command from the
ABSOLUTA
App or
from an
ABSOLUTA M-Touch
keypad (see
"USER MANUAL > Touch Keypad Operations
> Scenarios").
Table 16
Remote Command events.
Caller ID to Tel.
... the control panel receives a call from the
telephone number (see "Caller ID over GSM
events").
SPOT EVENT!
Table 17
Caller ID over GSM events.
EVENTS
OCCURS WHEN...
ENDS WHEN...
Light Above High
Threshold on
Zone
... the zone illuminance exceeds the
Light High
Threshold
(1).
… the zone illuminance falls below the
Light
High Threshold
(1).
Light Below Low
Threshold on
Zone
… the zone illuminance falls below the
Light
Low Threshold
(1).
... the zone illuminance exceeds the
Light Low
Threshold
(1).
Temperature
Above Very Hot
Threshold on
Zone
… the zone temperature remains above the
Very hot: Threshold
for the time set in
Very hot:
Wait before alert
(1).
… the zone temperature remains at least 1°C
below the
Very hot: Threshold
for the time set in
Very hot: Wait before restore
(1).
Temperature
Below Cold
Threshold on
Zone
… the zone temperature remains below the
Cold: Threshold
for the time set in
Cold: Wait
before alert
(1).
… the zone temperature remains at least 1°C
above the
Cold: Threshold
for the time set in
Cold: Wait before restore
(1).
Temperature
Below Freezing
Threshold on
Zone
… the zone temperature remains below the
Freezing: Threshold
for the time set in
Freezing:
Wait before alert
(1).
… the zone temperature remains at least 1°C
above the
Freezing: Threshold
for the time set
in
Freezing: Wait before restore
(1).
Temperature
Above Freezer
Threshold on
Zone
… the zone temperature remains above the
Freezer: Threshold
for the time set in
Freezer:
Wait before alert
(1).
… the zone temperature remains at least 1°C
below the
Freezer: Threshold
for the time set in
Freezer: Wait before restore
(1).
Table 18
Events related to smart wireless detectors:
1)
see the
Wireless Module
>
Wireless Detectors
option group.