Partitions
Select the Keypad Partitions. The Keypad
will be able to control (Arm, Disarm, etc.) ONLY the En-
abled Partitions.
+
Keypads need not necessarily be enabled on Parti-
tions, and can be used for programming, viewing
and other non-command related purposes.
n
Expander In
The Expander In option group will allow you to enroll the
Input Expanders located on the
M-IN/OUT
Expanders
the
PREMIUM
and the
ABSOLUTA T-Line
keypads
connected to the BPI bus
1
.
+
For information regarding the
Enabled
and Label
options, refer to “Configuration”.
Inputs
Select the number of inputs on board the de-
vice: only the relevant terminals will therefore be dis-
played in the
Zones
option group.
n
Expander Out
The Expander Out option group will allow you to enroll
the Output Expanders located on the
M-IN/OUT
Ex-
panders, on the
PREMIUM
and
ABSOLUTA T-Line
keypads
, connected to the BPI bus
1
.
+
For information regarding the
Enabled
and Label
options, refer to “Configuration”.
Outputs
Select the number of outputs on board the de-
vice: only the relevant terminals will therefore be dis-
played in the
Outputs
option group.
n
Key Readers
The
Key Readers
option sub-group will allow you to en-
roll and set up Key Readers. You must set up the Op-
tions and the Arm Modes for each
Partition
, as follow.
+
For information regarding the
Enabled
and Label
options, refer to “Configuration”.
EN50131
If this option is enabled, in standby mode the
Readers’ LED’s are turned off, regardless of the Parti-
tion status.
Default:
enabled.
e
In order to comply with the EN50131-1 and
EN50131-3 standards, this option must be en-
abled.
3
This option is ENABLED and locked (cannot be
changed) on Grade 3 Control Panels.
Automation Only
If
enabled,
the
Key
Reader
CANNOT arm or disarm partitions.
The
Valid Key
and
Valid Key on Key reader
occur all
the same, so the Key Reader can be used for automa-
tion operations like opening a gate:
Ø
a Key used on the Key Reader with this option en-
abled will only cause the gate to open;
Ø
the same Key used with another Key Reader with
this option disabled will cause the Areas to be
armed/disarmed.
Default:
disabled.
+
If this option is enabled, it is NOT possible to set the
options
Yellow
and
Green
but only for the parti-
tions on which the Key Reader is enabled (see
“Partitions”).
Partitions
Select the Partitions on which the Key
Reader is enabled.
+
Commands performed by the Key Reader will af-
fect ONLY the Partitions common to both the
Reader and Key in use.
For example, if you attempt to Arm the system at a
Reader that is enabled on Partitions no. 1 and no. 2,
with a Key that is enabled on Partitions no. 1 and no. 3,
ONLY Partition no. 1 will Arm (Partition no. 1 is common
to both the Reader and Key).
Yellow
This option will allow you to set up the
A Mode
Arming configuration. If an
A Mode
Arming request is
made at a Reader, the Partitions will Arm/Disarm in ac-
cordance with the programmed configuration, as
follows:
Ø
No Action
— the status of the corresponding Parti-
tion will remain unchanged;
Ø
Away
— the Partition will Arm;
Ø
Stay — the Partition will Arm in Stay mode (i.e.
Zones with the
Internal
Attribute will be Bypassed);
Ø
Instant Stay
— the Partition will Arm in Stay mode
with zero Entry Delay;
Ø
Disarm
— the Partition will Disarm.
Green
As per the
Yellow
option but for
B Mode
.
ABSOLUTA Plus
PROGRAMMING FROM THE PC
43
1
The M-IN/OUT Expander is seen as an Input Expander and/or as an Output Expander, depending on how it is
programmed (refer to the M-IN/OUT’s instructions for more information). If the M-IN/OUT Expander is programmed
as an Input and Output Expander, it must be enrolled as an Input Expander and as an Output Expander. For
example, if you have programmed an M-IN/OUT Expander as an Input Expander and Output Expander, and
assigned it address no. 1, you must enroll Input Expander no. 1 and Output Expander no. 1.