8.
On the left of the
Account Name
window, select
Absoluta Plugin
from the account control panel
branch, then enter the control panel
Serial Num-
ber
24
and press
Save
.
9.
Open the Customer Account and select Global
Download
, Global Upload
, or Communicate
Tags
.
10.
Select
Cellular (IP remote)
from the
Connection
Type
menu, then press
OK
.
11.
Type the public IP address of the router to which the
PC is connected in the option
Public IP Address
and select the port to access BOSS (
BOSS Exter-
nal Port
): ask the network administrator or see the
router’s instructions.
12.
If this is the first time installed, press
APN Settings
and set the
APN Name
,
User Name
, and
Pass-
word
for GPRS services (ask the operator of the
GPRS service).
+
Make sure to type the correct APN for WAP/GPRS
access - otherwise some functions may be limited.
13.
Prepare an SMS message as outlined in the
SMS
Message Generator
window then press
OK
.
14.
Send the SMS to the Control Panel GSM Module
number before the
Connection Timeout
time has
passed (see step no. 6).
After receiving the SMS message, if correct, the Control
Panel opens a remote connection via GPRS with the
BOSS application: at this point, options can be down-
loaded/uploaded, as outlined in the section “How
Downloading/Uploading the Options”, and the control
panel can be managed through the Status page.
+
On the router connected to the BOSS PC the for-
warding port from the
BOSS External Port
(factory
setting
51004
) to port
51004
(internal BOSS port,
CANNOT be changed) must be configured: request
router instructions from the network administrator.
Connection via LAN (IP)
To set up connection via
LAN (IP), proceed as described below (see “APPENDIX
> Connection via IP” for further information.
1.
Select the Customer Account properties (right click
on the Customer Account’s name, then
Proper-
ties
).
2.
On the left of the
Account Name
window, select
the account control panel, in the
Panels/Modules
branch.
3.
Type the Installer PIN in the option
BOSS Access
Code
(default
0104
or
00104
for Grade 3 Control
Panels).
4.
Select
Absoluta Plugin
from the
Module
menu
then press
Add
.
5.
On the left of the
Account Name
window, select
Absoluta Plugin
from the account control panel
branch, then select
IP
from the
Connection Type
menu and press
Add
.
6.
On the left of the
Account Name
window, select
IP
from
Absoluta Plugin
branch then enter the IP ad-
dress and the IP Module port
25
in the
IP
(factory set-
ting 192.168.0.101) and
Port
options (factory
setting 3062) respectively and press
Save
: at this
point it is possible to download/upload options as
outlined in the section “How Downloading/Up-
loading the Options”, and manage the Control
Panel via the
Status
page.
Connection via Internet (remote IP)
To set up con-
nection via Internet (remote IP), proceed as described
below (see “APPENDIX > Connection via IP” for further
information.
1.
Select the Customer Account properties (right click
on the Customer Account’s name, then
Proper-
ties
).
2.
On the left of the
Account Name
window, select
the account control panel, in the
Panels/Modules
branch.
3.
Type the Installer PIN in the option
BOSS Access
Code
(default
0104
or
00104
for Grade 3 Control
Panels).
4.
Select
Absoluta Plugin
from the
Module
menu
then press
Add
.
5.
On the left of the
Account Name
window, select
Absoluta Plugin
from the account control panel
branch, then select
IP (Remote)
from the
Connec-
tion Type
menu and press
Add
.
6.
Press
Save
to leave the factory settings
26
for the re-
mote IP connection and go to step no. 8, otherwise
read the following step.
96
Expandable Hybrid Control Panel
24
See “System Options > General > Serial Number” or “KEYPAD OPERATIONS > 3.2) View the Firmware Version” to
obtain the Control Panel Serial Number.
25
See
IP Address
and
Local BOSS Incoming Port
in
IP
Options Group.
26
The factory settings for remote connection via IP require the Absoluta Server to pass the public IP address for the
PC on which BOSS is installed (option
Auto detect
ENABLED) and the
BOSS External Port
51004 to the IP
Module