Serial Number
Shows the panel’s serial number.
+
This is a read-only option.
Keypad Language Selection
Select the language for
the keypad messages.
Bell Cutoff
Set the duration of the
Zone Alarm
event
when the
Real Time
option is DISABLED (see Zones
options). This option also determines the duration of
partition Alarm.
Valid entries:
5 through 15.000 seconds in 1-second steps.
Default:
180 seconds (3 minutes).
+
Since an alarm is detected, before the end of this
time,
it is no possible to activate again the siren
.
The siren will be activated only for a new event will
occur after this time.
Country Selection for Tone Settings
This is the same
option as in the
Advanced Call
sub-group.
+
If your country is not in the list or if you have prob-
lems with the phone line, select
Custom
and set
the parameters manually in the
Advanced Call
sub-group.
Ignore Log Limit
If
NO
, the logger records maximum
5 equal events during an arming period.
If
YES
, there is no limit to the equal events recorded in
the logger.
Default:
No.
e
In order to comply with the EN50131-1 and
EN50131-3 standards, this option should be
NO
.
Panel AS Tamper
In this option you can enable the
functioning of the external siren about the Tamper. You
can choose between:
AS Balanced Tamper
and
Ex-
ternal siren tamper
.
Default:
External siren tamper.
e
In order to comply with the EN50131-1 and
EN50131-3 standards, this option should be
Exter-
nal siren tamper
.
Supervised Siren
If enabled, the Control Panel can
detect and signal short circuits and interruption on the
terminal
+A
line.
+
Terminal
+A
must be wired as indicated in
“INSTALLATION>Connecting
Signalling
De-
vices>Supervised Outputs”.
Dialer Priority
Every event may perform the following
actions:
Ø
Speaker
: Voice Message on AS100 Audio Station.
Ø
Digital/Vocal calls
: Digital or Voice calls on the tele-
phone landline (PSTN) or on the GSM line (if the
ABS-GSM
Module is installed).
Ø
SMS
: sending an SMS by GSM (if the
ABS-GSM
Module is installed);
Ø
Receiver Event
, event reporting via GPRS and/or IP
to the Sur-Gard SYSTEM
I
/
II
/
III
receivers;
Ø
Push Event
, event reporting via e-mail and/or the
ABSOLUTA
app.
Choose the order of priority for actions:
Ø
Speaker - Digital/Vocal calls - SMS - Receiver
Event - Push Event
;
Ø
Speaker - SMS - Digital/Vocal calls - Receiver
Event - Push Event
;
Ø
Speaker - Receiver Event - Digital/Vocal calls -
SMS - Push Event
;
Ø
Speaker - Receiver Event - SMS - Digital/Vocal
calls - Push Event
;
Ø
Speaker - Digital/Vocal calls - Receiver Event -
SMS - Push Event
;
Ø
Speaker - SMS - Receiver Event - Digital/Vocal
calls - Push Event
;
Ø
Speaker - Push Event - Digital/Vocal calls - SMS -
Receiver Event
;
Ø
Speaker - Push Event - SMS - Digital/Vocal calls -
Receiver Event
;
Ø
Speaker - Push Event - Receiver Event - Digi-
tal/Vocal calls - SMS
;
Ø
Speaker - Push Event - Receiver Event - SMS -
Digital/Vocal calls
;
Ø
Speaker - Push Event - Digital/Vocal calls - Re-
ceiver Event - SMS
;
Ø
Speaker - Push Event - SMS - Receiver Event -
Digital/Vocal calls
.
Default:
Speaker - SMS - Digital/Vocal Calls - Receiver
Event - Push Event.
Hardware Type
This is an read-only option shows the
type of electronic card in the control panel:
Ø
Standard Audio Quality
;
Ø
Enhanced Audio Quality
.
Reset alarm/tamper memory on arming
(Master code - keys)
Reset alarm/tamper memory on arming
(SuperUser code - MasterUser code - keys)
If
en-
abled, the alarm and tamper events stored during an
arming period will be deleted the next time the system is
armed using a
Super
Code (Grade 3 panels only), a
Master
Code (only deletes alarm memories on Grade 3
panels) or a Key.
Default:
enabled.
+
ONLY the memory relating to the common Partitions
with PIN/Key and Keypad/Reader will be deleted.
+
If the
INCERT
option is enabled alarm memories
ONLY will be cleared.
ABSOLUTA Plus
PROGRAMMING FROM THE PC
61