72
Expandable Hybrid Control Panel
EVENTS
OCCURS WHEN...
ENDS WHEN...
Alarm on zone
... the zone detects alarm conditions (1).
... the zone restores to standby status.
Tamper on zone
... the zone detects tamper conditions (1).
... tamper conditions are no longer present on
the zone.
Zone
Fault/Masking
... the zone is a wired zone, and detects a fault
condition (2) or, the zone is a wireless zone,
and the associated detector is masked (3).
... the zone is a wired zone, and the fault condi-
tion ends or, the zone is a wireless zone, and
the associated detector is no longer masked.
Real time of
Zone
... the voltage (resistance) on the zone is in
the alarm range.
... voltage (resistance) on the zone restores
to standby range.
Bypass Zone
... the zone is bypassed.
... the zone is unbypassed.
Loss of
Wireless
Detector (5)
... the transceiver cannot communicate with the
wireless detector (4).
... the transceiver receives a valid signal from
the wireless detector.
Low
Battery on
Wireless
Detector (5)
... the wireless detector transmits a low battery
message to the transceiver (6).
... the wireless detector transmits a charged
battery message to the transceiver (6).
Table 11
Zone Events.
1)
Zones go into alarm and tamper status depending on the settings of the
Zones
option group.
2)
See the
Balance
>
Triple End of Line
and
Type
>
Zone Fault
options in the
Zones
option group.
3)
See the
Anti-Masking
and
Anti-Masking PIR
options in the
Wireless Module
>
Wireless Detectors
option group.
4)
The
Supervision
option of the wireless detector is enabled (see the
Wireless Module
>
Wireless Detectors
option group,
and the
Wireless Supervisory Window
has expired (see the
Wireless Module
>
General
option group) since the last time
the transceiver was able to communicate with the detector.
5)
The number of the wireless detector refers to the position assigned to the detector in the
Wireless Module
>
Wireless
Detectors
option group, and not to the number of the logical zone to which the detector is assigned.
6)
The wireless detector communicates the status of its battery along with each message sent to the transceiver.
EVENTS
OCCURS WHEN...
ENDS WHEN...
Generic alarm
on partition
... a Zone (any type) — associated with the Par-
tition detects Alarm conditions.
... ALL
Alarm
events generated by Zones — as-
sociated with the Partition restore to standby.
Tamper alarm
on partition
... a Zone — associated with the Partition de-
tects Tamper conditions .
... ALL
Tamper
events generated by Zones —
associated with the Partition restore to standby.
Fire Alarm on
partition
... a Zone — associated with the Partition de-
tects a
Fire Alarm
condition.
... ALL
Fire
Alarm events generated by Zones
associated with the Partition restore to standby.
Memory Alarm
on Partition
... the
Generic alarm on partition
Event oc-
curs.
... the Partition Resets.
Alarm Stop on
Partition
... a
Stop Alarms
request is made using a User
PIN enabled for the Partition.
... the Control panel exits the
Stop Alarms
sta-
tus.
Global Arming
Partition
... the Partition Arms in Away Mode.
... the Partition Arms in Stay Mode or Stay
Mode with Zero Delay.
Partial Arming
Partition
... the Partition Arms in Stay Mode or Stay
Mode with Zero Delay.
... the Partition Arms in Away Mode or Dis-
arms.
Autoarming
Warning
Partition
... there are 10 minutes left before automatic
arming of the partition.
SPOT EVENT!
Arming Refused
on Partition
... a request of Arming on the partition was re-
fused due to block condition.
SPOT EVENT!
Automatic
Arming Refused
on Partition
... during auto-arming, a Partition's zone is on
alarm. At default, the Panel must inhibit the
arming without activating the alarm.
SPOT EVENT!
Disarming
Partition
... the Partition Disarms.
... the Partition Arms in Away Mode or Stay
Mode or Stay with Zero Delay Mode.
Schedule on
Partition
... the scheduler arms the partition.
...the scheduler disarms the partition.
Entry Time on
Partition
... one of the
Entry delay
Zones belonging to
the Partition detects Alarm conditions and the
Partition is Armed in Stay or Away Mode.
... the Partition Entry Time expires or the Parti-
tion Disarms.
Table 12
Partition Events