10-11
Alarms #:
Description:
Causes et verifications
HR8514
BAC relay has remained closed.
Verify BAC relay operation, because it remained closed
when the CPU BAC input deactivated.
Verify electrical wiring of the in-car stop switch (refer
to drawings).
HR8515
Custom, refer to user manual list.
HR8600
FCSB relay has remained closed.
Verify FCSB relay operation, because it remained
closed when the CPU FCSB input deactivated
HR8601
FCSB relay did not activate.
Verify FCSB relay operation, because it did not activate
when the CPU FCSB input activated
HR8602
Reset governor switch or relay remained closed
Verify reset switch or RG relay
HR8603
ACC or ACC1 relay did not activate.
Verify ACC or ACC1 relay operation, because it did not
activate when the CPU ACC or ACC1 input activated
HR8604
ACC or ACC1 relay has remained closed.
Verify ACC or ACC1 relay operation, because it
remained closed when the CPU ACC or ACC1 input
deactivated
HR8605
RED relay did not activate.
Verify RED relay operation, because it did not activate
when the CPU RED input activated
HR8606
RED relay has remained closed.
Verify RED relay operation, because it remained closed
when the CPU RED input deactivated
HR8607
LU relay did not activate.
Verify LU relay operation, because it did not activate
when the CPU LU input activated
HR8608
LU relay has remained closed.
Verify LU relay operation, because it remained closed
when the CPU LU input deactivated
HR8609
LD relay did not activate.
Verify LD relay operation, because it did not activate
when the CPU LD input activated
HR8610
LD relay has remained closed.
Verify LD relay operation, because it remained closed
when the CPU LD input deactivated
HR8611
HDL relay did not activate.
Verify HDL relay operation, because it did not activate
when the CPU HDL input activated
HR8612
HDL relay has remained closed.
Verify HDL relay operation, because it remained closed
when the CPU HDL input deactivated
HR8613
24 Volts DC +A power failure.
Verify protection fuse. The filament could be defective.
There may have been short-circuited.
Summary of Contents for 2000 Series
Page 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Page 2: ......
Page 5: ......
Page 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Page 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Page 28: ...6 3 Standard tape selector installation ...
Page 44: ...6 19 ...
Page 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Page 60: ...10 2 ...
Page 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...