10-13
Alarms #:
Description:
Causes et verifications
(See CANBUS manual)
HR8801
Communication loss with the JRT-CAN-HCI
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8802
Communication loss with the Car B duplex
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8803
Communication loss with the module 0 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8804
Communication loss with the module 1 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8805
Communication loss with the module 2 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8806
Communication loss with the module 3 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8807
Hall network was opened
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8808
Communication loss with the module 4 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8809
Communication loss with the module 5 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8810
Communication loss with the module 6 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8811
Communication loss with the module 7 JRT-CAN-24IO
Verify connections, supply and switches configuration.
(See CANBUS manual)
HR8812
Light curtain fault.
For a vertical sliding door freight elevator, the photocell
proper functioning must be checked before closing the
door. Check the photocell proper functioning.
HR8813
Custom, refer to user manual list.
HR8814
Custom, refer to user manual list.
HR8815
Door jammed on opening.
The elevator tried to completely open the door 3 times
without succeeding. The alarm activates once an
opening relay (FOP, ROP) is activated lasting more
than the protection delay. Ensure the door operators are
Summary of Contents for 2000 Series
Page 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Page 2: ......
Page 5: ......
Page 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Page 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Page 28: ...6 3 Standard tape selector installation ...
Page 44: ...6 19 ...
Page 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Page 60: ...10 2 ...
Page 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...