SECTION 4 - MACHINE OPERATION
4-22
– JLG Lift –
3121773
•
If the charge is less than 10%, in addition
to the audible warning signal, reduced
speed is activated and an icon comes on
in position 4 on the platform station LCD
display.
To start charging the battery connect the main AC power
supply to the
AC socket
(item 1 - photo)
located on the
right rear of the machine next to the electric engine.
After a few seconds the
charge indicator
(item 2 - photo)
located on the right hand side of the machine on top of the
lithium-ion battery pack turns red, meaning the battery has
started charging.
1
2
THE BATTERY CHARGER SUPPLIED WITH THE LIFT WAS DESIGNED TO
ENSURE SAFE AND RELIABLE PERFORMANCE. IT IS ALREADY FITTED ON THE
MACHINE AND DOES NOT NEED ANY ADJUSTMENT OR CONFIGURATION BY
THE USER; NONETHELESS, TO AVOID INJURY AND DAMAGE TO THE BATTERY
CHARGER, THE FOLLOWING ESSENTIAL PRECAUTIONS MUST BE OBSERVED:
•
Carefully read installation instructions contained in this
manual. For future reference, keep manual in a safe
place.
•
Do not place battery pack near heat sources.
•
As battery charger is sealed without forced ventilation,
its performance depends on ambient temperature and
type of installation.
•
Be certain type of power supply available corresponds
to voltage specified and indicated on the battery char-
ger rating plate or in this Operation/Maintenance Man-
ual. If any questions, contact your local JLG Service
Center or the local electrical company.
•
An AC class circuit breaker can be used as a protection
device for the battery charger power supply, however it
is recommended to use a class A or even better class B
device.
•
In regard to safety and electromagnetic compatibility,
the battery charger features a three pin plug with
ground, which can only be plugged into an grounded
socket. If the plug does not go into the socket, most
probably the socket is old and not grounded. In this
To