SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-20
3121783
9.
Upon verification tighten the counter-nuts and
reattach any removed covers
Wear Pad Inspection
Check for distance between wear pads and boom sections.
Distance is to be no more than 1/32nd inch.
Turntable Attach Bolts
Ensure the bolts of the coupling elements (turntable) are
torqued to 183 ft-lb. (248 Nm)
Battery Maintenance and Charging - Diesel/AC-Electric
NOTE:
The battery is a maintenance free battery. Do NOT
attempt to open a maintenance-free sealed battery.
External Battery Charger Use
WHEN AN EXTERNAL BATTERY CHARGER IS TO BE USED, CHARGING HAR-
NESS MUST BE PLUGGED INTO A GROUNDED RECEPTACLE. IF RECEPTACLE IS
NOT GROUNDED AND A MALFUNCTION SHOULD OCCUR, THE MACHINE
COULD CAUSE SERIOUS ELECTRICAL SHOCK.
1.
Open battery cover.
2.
Disconnect the terminal clamps from the battery
poles.
3.
Connect the cables of the charger to the battery
poles. and turn on the battery charger
NOTE:
Re-charge voltage should never exceed 14.7 volts and
the load intensity shall be 0.2% of the value indicated
below and on the lid of the battery.
4.
When charging is completed turn off the battery
charger before disconnecting the cables from the
battery poles
5.
Return the terminal clamps to the battery poles
and lubricate with the appropriate product
6.
Close battery cover.
IT IS GOOD PRACTICE TO AVOID PRESSURE-WASHING ELECTRICAL/ELEC-
TRONIC COMPONENTS. IN THE EVENT PRESSURE-WASHING THE MACHINE IS
NEEDED, ENSURE THE MACHINE IS SHUT DOWN BEFORE PRESSURE-WASH-
ING. SHOULD PRESSURE WASHING BE UTILIZED TO WASH AREAS CONTAIN-
ING ELECTRICAL/ELECTRONIC COMPONENTS, JLG INDUSTRIES, INC.
RECOMMENDS A MAXIMUM PRESSURE OF 750 PSI (52 BAR) AT A MINIMUM
DISTANCE OF 12 INCHES (30.5 CM) AWAY FROM THESE COMPONENTS. IF
ELECTRICAL/ELECTRONIC COMPONENTS ARE SPRAYED, SPRAYING MUST
NOT BE DIRECT AND BE FOR BRIEF TIME PERIODS TO AVOID HEAVY SATURA-
TION.
To
order
go
to
Discount-Equipment.com