SECTION 4 - MACHINE OPERATION
3121783
4-17
Each outrigger has a orange light installed. All lights will be
on steady if outriggers are positioned to the full operation
area. Lights will be flashing if any of the outriggers are posi-
tioned in the restricted operation area. No lights will be on if
the outriggers are not set properly.
IF ONE OF THE ORANGE LIGHTS LOCATED ON EACH OUTRIGGER SHOULD
FLASH OR REMAIN ON WHEN THAT OUTRIGGER IS LIFTED FROM THE
GROUND, STOP THE MACHINE IMMEDIATELY AND CALL A QUALIFIED JLG
SERVICE TECHNICIAN AS THIS INDICATES A PROBLEM WITH THE CORRE-
SPONDING OUTRIGGER MICRO SWITCH.
IF SLOPE EXCEEDS 13°, THE MACHINE IS NOT CAPABLE OF PROPERLY SET-
TING OUTRIGGERS AND LEVELING ITSELF. OPERATION OF BOOM AND PLAT-
FORM FUNCTIONS WILL NOT BE ALLOWED IN THIS CONDITION. THE
MACHINE IS CONSIDERED STABILIZED WHEN LEVELED TO LESS THAN 1° AND
TRACKS ARE LIFTED AT LEAST 2 IN. (5 CM) FROM THE GROUND.
STABILIZING MACHINE WITH AN INCLINATION DEGREE HIGHER THAN THE
ONE ALLOWED COULD CAUSE INSTABILITY OF THE MACHINE
If the platform ladder is higher than 16 in. (40 cm) off the
ground when the ladder is lowered, when setting the
machine on outriggers from the ground position, lower the
outriggers until the ladder is less than 16 in. (40 cm) off the
ground. Then enter the platform to properly set the machine
up on outriggers.
OL00610
To
order
go
to
Discount-Equipment.com