SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-38
3121783
12.
The area around the cell will be covered by a black
carbonaceous deposit which contains metallic
parts of the cell. Cover the carbonaceous residue
with a 50/50 mixture of baking soda and vermicu-
lite or other absorbent material. Avoid contact
between the metallic residue and charged cells as
this condition may cause a short.circuit.
13.
Place the contaminated material in a sealable plas-
tic bag and remove the excess air.
14.
Seal the bag.
15.
Place a cup of vermiculite in a second bag, place
the first bag in the second and seal it.
16.
Clean the area with plenty of water and keep
cleaning with water and soap.
17.
Dispose of hazardous material in accordance with
the local legislation in force.
First Aid In The Event Of Contact With The Electrolyte;
EYES
Immediately wash the eyes in abundant running water for at
least 15 minutes, keeping the eyelids open and flushing the
eye and back of the eyelid. Immediately seek medical help.
SKIN
Wash in cold water under a shower, remove contaminated
garments. Continue washing for at least 15 minutes. Seek
medical help where necessary.
RESPIRATORY TRACT
Move person(s) outdoors into the open air. If person(s) has
difficulty breathing, have oxygen administered by trained
personnel. If breathing stops apply mouth-to-mouth resus-
citation and immediately seek emergency medical help.