JVM-407B
Automatic copying of controller data
Automatic retrieval of data file information
The JVM-407B is able to load a data file before the application program is
launched.
The data file must be named
register.da
and stored to the folder
App
.
The table below shows how the device retrieves data file information:
Step
Description
1
If the data file
register.da
has been stored to the folder
App
, the device
detects this file on its next launch.
2
The devices reads in the file.
3
The device maps the values to registers.
4
Once the device has read in the file, it deletes the data file.
5
The device loads the application program.
Read access to the file
register.da
Prerequisites
Process flow