20
Learning to Use the Lean Clean 360 Cleaning System
Connecting the Drain Station
If your Lean Clean 360 includes the optional 5-gallon drain station, follow
these steps to install it:
1.
Locate the following parts included with the drain station:
PVC drain pipe
Flexible air line
2.
Locate the drain station near the Lean Clean 360.
3.
Using the PVC pipe, connect the main drain from the Lean Clean to
the inlet on the drain station tank (Figure 5).
4.
Connect user-supplied flexible hose from outlet of the pump to your
drain or waste collection tank.
Expert Advice
—
Depending upon the contaminates you are removing with
the Lean Clean 360-1, wash and rinse water disposal may require treatment to
meet national, state, and local environmental regulations. Before connecting the
Lean Clean 360-1 to a drain, ensure the drain is appropriate for the contaminates in
the rinse and wash water.
5.
Connect the compressed air line from the Lean Clean to the to air
inlet on the drain station.
6.
Connect the high and low level signal cables from the drain station to
the terminals on the Lean Clean control panel.
7.
Connect the solenoid control cable from the solenoid to the terminal
on the Lean Clean 360-1 control panel.