Learning to Use the Lean Clean 360 Cleaning System
11
Oleophilic (oil attracting) coalescing tubes capture, agglomerate, and float oil
globules to the surface where an adjustable weir discharges the oil from the
separator. The tubes consistently remove oil globules 20 microns and larger at
a capacity of 10 mg/l. The coalescer removes only oil, not chemistry.
External PLC Programming Port or Modem
The external PLC programming port enables programming from
an external computer. By adding the optional modem, JENFAB engineers can
make programming changes or diagnose problem remotely, lowering service
and troubleshooting costs.
Stack Light
A red/amber/green stack light located on the top of the control panel
indicates a ready, standby, or fault condition.
Auto Rust Inhibitor
The rust inhibitor option enables rust inhibitor to be applied to parts during
the fresh water rinse (fresh water rinse option required). A Dosatron injector
metering valve added to the fresh water line automatically mixes rust inhibitor
with the fresh water at the appropriate concentration, regardless of flow and
pressure variations.
Drain Station
A freestanding 5-gallon stainless steel holding tank with air-driven diaphragm
pump and high/low level control linked to the PLC. Where a gravity drain is
not available, the drain station enables collection and pumping of the Lean
Clean drain water to an elevated drain or waste water tank.