background image

Operating Instructions

Industrial cleaner
IR 6001

To prevent accidents
and machine damage,UV
read these
instructions

before

installation or use.

M.-Nr. 04 271 821

Summary of Contents for IR 6001

Page 1: ...Operating Instructions Industrial cleaner IR 6001 To prevent accidents and machine damage UV read these instructions before installation or use M Nr 04 271 821...

Page 2: ...ying time 13 Operation Key switch 16 Turning on 16 Program sequence 17 Interrupting a program 18 Turning off 18 Applications Electronics Applications Metal Cleaning IMPORTANT SAFETY INSTRUCTIONS Appli...

Page 3: ...a Service Panel b TA Drying unit c MCU d Filter combination e Reactivation socket for salt container water softener Guide to the machine 3...

Page 4: ...MCU f Main power switch g Key switch h Display field i Operating control pad j Serial interface Guide to the machine 4...

Page 5: ...Control indicators k On Off indicator light l In operation indicator light m Fault Error indicator light n DOS dispenser level indicator light o Door release Guide to the machine 5...

Page 6: ...owing notes to maintain safe procedures Dot not install the machine in an area where a danger of explosion may be present The machine should be installed repaired and maintained by an authorized Miele...

Page 7: ...is completely drained of any residual water and cleaning agent Make the door lock inoperative so that children cannot accidentally shut themselves in The following points should be observed to avoid d...

Page 8: ...orrosion ensure that solutions or steam containing acid salts do not come into contact with the outer steel casing of the machine Do not use any cleaning agent which adheres to file dust or filings De...

Page 9: ...city of the items in the load and the amount of water remaining The machine can be programmed and a variety of baskets and inserts used depending on specific needs Special cleaning programs can be wri...

Page 10: ...the user to adapt the process to individual requirements With a large memory capacity up to 64 different programs can be stored and the selected according to the load to be cleaned Different keys are...

Page 11: ...or or mobile unit is inserted into the machine it should be 3 8 higher than the water inlet in the roof of the cabinet If it is not adjust the adapter by Loosening the lock ring Pushing up the adapter...

Page 12: ...atic dispensing of liquid additives DOS 10 30 injector pump for dispensing acid additives Dispensing capacity is 10 ml 30 secs channel 9 2 DOS 60 30 injector pumps for dispensing liquid cleaning agent...

Page 13: ...tainer has not been refilled in time and the despensing system was allowed to empty completely Close the door Set the key switch to position II Turn the main switch to I Select program 14 DOS FILL DOS...

Page 14: ...e T2 temperature Start by pressing the touch pad P twice then proceed as for temperature T1 Note Header parameters which have not been programmed do not appear in the display Altering the TA drying te...

Page 15: ...40 min example Touch pad Display XXX PROGRAM NAME P XXX T1 094 P XXX T2 070 P XXX TA 090 P XXX ZA 030 U XXX ZA 031 M XXX ZA 031 M XXX ZA 032 M XXX ZA 040 S XXX ZA 040 S XXX PROGRAM NAME _ number flash...

Page 16: ...election Key switch setting II Turn main switch to I on Select program with keys O or M The program description appears in the display field 1 Wafer chip WAFER CHIP 2 Semiconductors HALBLEITER 3 Solde...

Page 17: ...rim rinse final rinse drying or the Codetext Program sequence After starting the program proceeds automatically It is finished when the in operation light l goes out y The Fault Error indicator light...

Page 18: ...filter in the TA drying unit See page on drying unit maintenance REGENERIER REGENERATE Replenish the water softener with salt see Reactivating water softener Interrupting a program Once a program has...

Page 19: ...purified ion free water is used throughout DI water For surface mount or hybrid technology the use of water soluble soft solder paste is recommended A high standard of cleaning can then be achieved by...

Page 20: ...nding on quality standard required reduces the risk of damage to the material which may be adversely affected by non purified water after prolonged use Example 8 solder frames L 18 11 16 x W 16 29 32...

Page 21: ...citric or phosphoric acid base 0 1 0 15 slightly acidic citric or phosphoric acid base 0 1 0 15 Notes a second cleaning agent may be necessary where foam occurs use silicone free anti foaming agent d...

Page 22: ...wash is advisable with polishing grinding pastes to identify the most suitable cleaning processes A final rinse with de ionized water is often necessary especially with non ferrous metals to achieve t...

Page 23: ...zed applications only as described in these Operating Instructions Using it for purposes other than those for which it is designed could cause damage or injury The manufacturer cannot be held responsi...

Page 24: ...ther operators When using this machine at temperatures between 158 F and 203 F 70 C and 95 C be especially careful not to scald or burn yourself Baskets and inserts must first cool down Any water whic...

Page 25: ...arise with their use for example damage to rubber and synthetic materials In critical applications where stringent requirements have to be met it is strongly recommended that all process parameters su...

Page 26: ...with national and local water regulations Consult your local water authority Where discharge is indirect ensure that the waterborne residues do not exceed statutory limits Only equipment made or auth...

Page 27: ...lkaline cleaner 0 1 0 15 sometimes necessary for a citric acid based neutralizer when using alkaline cleaner with silica 0 1 0 15 addition of citric or phosphoric acid based neutralizer often brighten...

Page 28: ...rinding paste and giving a final rinse to clear the items of residues The quality of the final rinse depends on the quality of the water With polishing pastes it is advisable to investigate the suitab...

Page 29: ...l 9 and 14 between Steps 11 and 12 P 006 If no neutralizer and only a small amount 0 3 of cleaning agent is dispensed select P 007 If the cleaning agent is low foam delete Step 4 P 007 1 Characteristi...

Page 30: ...the addition of a minimal amount of a special cleaning agent in a purely aqueous system without the addition of solvents In these applications the cleaning process is carried out using de ionized wate...

Page 31: ...must be carried out twice in succession For each reactivation program you will need 4 4 lbs 2 kg reactivation salt granule size must be 1 4 mm The plastic salt container supplied as standard equipment...

Page 32: ...ds automatically and is finished when the l indicator light goes out Then Turn off the machine Open the door and remove the salt container Replace the plastic cap on the socket at the bottom of the wa...

Page 33: ...ral equipment The following connection cables are available from Miele 45 ft 15 m connection cable for short term connection between the MCU front interface and a PC or printer 45 ft 15 m connection c...

Page 34: ...L MODE W BAUDRATE nnn U BAUDRATE nnn O O BAUDRATE XXX S BAUDRATE XXX 2 Select communication type PRINT printer connection Touch pad Display BAUDRATE XXX a M FUNCTION PROG U FUNCTION PROG M FUNCTION PR...

Page 35: ...ger Report printout manager This program can be used to record and store report data load from a data carrier and print from an Epson compatible or HP LaserJet printer MCU programming software In addi...

Page 36: ...if necessary cleaned after every program Glass fragments needles pieces of wire etc may have collected in this filter and could cause injuries Cleaning the coarse filter Press the two tabs inwards and...

Page 37: ...ter take hold of the two tabs turn twice in a counter clockwise direction and remove together with the flat filter Clean all the filters Replace the filter combination securely in the reverse order in...

Page 38: ...n off the water valves Disconnect the inlet hoses Remove the filter housing from the water valve Remove the filer insert 1 from the housing and clean or replace if necessary Clean the filter located i...

Page 39: ...the filter should face the rear Position the perforated plate at the base and press into place at the top The edges should face forward On replacing the inlet grill it should click into place Exchangi...

Page 40: ...isplayed Overheating can occur if large items cover the heater elements preventing them from transfering heat to the water It can also occur if the filters in the wash chamber are blocked or too littl...

Page 41: ...ot exceed 150 F 65 C recommended 140 F 60 C The hot water supply hose is marked with red tape This hose may also be connected to a cold water supply if hot water is not available 3 DI water connection...

Page 42: ...ing tank This hose must not be shortened An increase in length up to 13 ft 4 m is possible using 7 8 22 mm internal diameter hose available through Miele Technical Service Do not decrease he internal...

Page 43: ...h the machine but must be provided on site if required The tank should be positioned to the left of the machine viewed from the front If the user wishes to connect a holding tank to the machine the fo...

Page 44: ...Warning and Safety instructions When disposing an old machine first make it unusable Disconnect or cut off the plug and cable For environmental and safety reasons ensure the machine is completely drai...

Page 45: ...41...

Page 46: ...Alteration rights reserved 2101 M Nr 04 271 821 00...