With this data you can calculate the following values:

Based on the following table, determine if the layout is

authorised as well as the deflector position:

CO2 must be measured at the terminal during rated operation 
and it must be 5.5%. If this is not the case, the deflector 
height must be adjusted.

CONNECTING GAS

The appliance is delivered fully equipped with:

-

A burner assembly installed in the combustion 
chamber (1)

-

A solenoid valve block and the gas fittings between 
the burner and the solenoid valve block (2)

-

A receiver connected to the solenoid valve block (3)

-

A power cord (4)

-

A remote control synchronised with the receiver

After installing the hood and the ducts, it is necessary to

verify again that the valve can move freely. In order to do so,

lift it several times at the maximum from the inside of the

fireplace.

ADJUSTING THE HEIGHT OF THE DEFLECTOR

Depending on the layout and the number of horizontal, 

vertical, oblique and elbow pieces, the height of the deflector 

in the appliance must be set to one of 6 positions. Position 1 

is the most open position (low draw) and position 6 the most 

closed position (strong draw).

Adjustment is done by removing the 2 screws from each 

bracket, retracting the bracket on the deflector to put it in the 

correct position and tightening the screws once more. Do this 

on each bracket individually to make it easier.

HOW TO CALCULATE THE DEFLECTOR POSITION

In order to verify and calculate the deflector position, a 
sketch of the required layout should be made, and the 
following table should be filled in.

Please note that the minimum requirements for configuration 

C11 are: 1 vertical metre + 1 elbow at 90

°

+ horizontal 

terminal.

Description

Abbreviation

Measured 

value

Number of vertical metres

(1)

…. metres

Number of horizontal metres

(2)

…. metres

Number of metres at an angle of 45°

(3)

…. metres

Number of elbows up to 45° (x0.5m)

(4)

…. metres

Number of elbows up to 90° (x1m)

(5)

…. metres

Description

Abbreviation

Results

Total resistance length 

= (1)+(2)+(3)+(4)+(5)

L

…. metres

Total vertical length = (1)

V

…. metres

Total horizontal length 

= (2)+(3)+(4)+(5)

H

…. metres

Total vertical length minus total 

horizontal length = V-H

R

…. metres

Conditions

Layout 

Authorisation

Deflector 

Position

L > 12

Non authorised

/

V < 1

Non authorised

/

(2) > 3

Non authorised

/

R < -1

Non authorised

/

-1 < R < 0

Authorised

1

0 < R < 1

Authorised

2

1 < R < 2

Authorised

3

2 < R < 3

Authorised

4

3 < R < 4

Authorised

5

4 < R

Authorised

6

Pressure release

valve

Deflector adjustement (x3)

Déflector

6

5

2

4

1

3

1

3

2

4

INSTALLATION OF THE APPLIANCE

1. INSTALLATION INSTRUCTIONS

Summary of Contents for EVA992GAZ

Page 1: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 2: ......

Page 3: ...ufficient load bearing capacity If an existing building does not meet this prerequisite adequate measures e g installation of a load distribution plate must be taken to enable the floor to support the...

Page 4: ...0 0 120 0 120 Burner pressure mbar 28 3 28 3 28 3 28 3 Burner injector 2x 120 100 COMMON CHARACTERISTICS Concentric system C11 130 200 C31 C91 100 150 Configuration C11 C31 C91 Minimum distance betwee...

Page 5: ...AL CHARACTERISTICS OF THE WALL MOUNTED APPLIANCE 816mm 1175mm 600mm 460mm 370mm 1680mm Adaptable ceiling height 820mm ACCESS HATCH Must remain accessible BASE Metal Brick Ceramic FIREPLACE Natural Gas...

Page 6: ...technical point of view based on the tables of paragraph How to calculate the deflector position If it is not an alternative layout must be determined Attention depending on the layout the appliance...

Page 7: ...he outside of the concentric system and combustible materials is 50mm The flue ducts must slide into each other correctly and form a stable whole Airtightness must be achieved according to POUJOULAT s...

Page 8: ...ign office must be respected in order to comply with the assembly and installation configuration The hood is to be positioned and fixed using the 3 brackets already installed on the fireplace Brackets...

Page 9: ...removing the 2 screws from each bracket retracting the bracket on the deflector to put it in the correct position and tightening the screws once more Do this on each bracket individually to make it ea...

Page 10: ...burner pressure must be checked during commissioning Please refer to the technical characteristics provided at the beginning of these instructions Warning This appliance is pre set and sealed at the...

Page 11: ...INSTALLATION OF THE APPLIANCE 1 INSTALLATION INSTRUCTIONS...

Page 12: ...operation and can change the flame appearance The appliance finishing paint is a special paint With high temperature strength that finishes hardening during the first ignitions It is very important no...

Page 13: ...o the plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas...

Page 14: ......

Page 15: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 16: ...or sparks open windows and doors close the gas supply tap and contact your installer Never use a flame to check for gas leaks Any operation inside the appliance must be performed by a qualified profe...

Page 17: ...of minutes This step is called bnd USING THE REMOTE CONTROL USING THE REMOTE CONTROL The remote control has been specifically designed to work with the gas inflow control system in your appliance It...

Page 18: ...24 heures USING THE REMOTE CONTROL The remote control has a screen and four buttons It provides easy control of the fireplace The settings can also be easily changed There are two adjustment menus Us...

Page 19: ...ary change is automatically cancelled Temporary stoppage of the program When using the programmer you can also temporarily turn off the fireplace Press the button when the fireplace is lit N B the des...

Page 20: ...button to exit the menu INSTALLATION MENU To select the Installation menu follow these steps Close the User menu if it is open Then hold down the button for 10 seconds The Installation menu lets you...

Page 21: ...alternately If a program has been selected the screen displays the status of the situation Malfunction of the temperature sensors of the remote control and the fireplace or sensor in the latter unava...

Page 22: ...he plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas ta...

Page 23: ...aler an installer or a user This warranty shall not cover appliances not repaired by duly trained specialists authorised by BORDELET Damage occurring during transport is not covered by this warranty b...

Page 24: ......

Page 25: ...Nameplate of your appliance...

Page 26: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...

Reviews: