background image

The following programs are available*:

-

A program with identical settings for each day

-

A program with different settings for the days of the week

and for the weekend.

-

A program with different settings for each day

The program is easy to enter: just set the start time and the

desired temperature for each period.

As the gas fireplace is a supplementary heating system, the

remote control that houses the temperature sensor must be

kept at a distance of more than 1.5 m from the fireplace.

The fireplace must have been previously installed and

connected to the gas supply network, the exhaust network,

the combustion air supply and the mains network.

Here in this case, it must be connected to the 220/240V AC

50/60Hz mains supply.

Inserting batteries in the remote control

Before using the remote control you must insert the two AA 

batteries (supplied). Once the batteries have been inserted, 

the remote control is ready for manual use and manual flame 

height adjustment. In order to save battery power the display 

turns off shortly after the last button press, unless the 

fireplace is turned on.

The factory setting for the timer is 15 minutes

Flame symbol

The appliance is designed to create attractive yellow flames.

The flame symbol indicates that your fireplace burner is on

and flame monitoring is active.

Communication with the remote control

The remote control can only communicate with the fireplace

appliance when it has been recognized by the

appliance’s

receiver.

If both appliances are turned on, registration is done

automatically within a matter of minutes. This step is called

"bnd"

USING THE REMOTE CONTROL

USING THE REMOTE CONTROL

The remote control has been specifically designed to work

with the gas inflow control system in your appliance. It has

been adjusted by us to ensure your fireplace works correctly.

The instructions below must be read before using the remote

control unit or the fireplace.

ECRAN ET COMMANDES

DISPLAY

CONTROLS

TURNING ON

The remote control lets you control your FIREPLACE

“manually”

or using the programmer*. You can adjust the

temperature and the height of the flames manually.

The programmer only regulates the temperature.

Display

Increase button
Decrease button
Stop / Standby button

Menu button

Manual operation

Programmer activated

Active programmer period

Fireplace closed (left) or open (right)

The fireplace is lit

The fireplace can be lit

Fireplace malfunction: it had to be reset

Low burner setting (left), high burner setting (right)

Operation in progress (e.g. ignition of the fireplace)

Malfunction

Fireplace is incorrectly plugged in to the mains

Radio Frequency (RF) communication

Low battery level (the symbol is flashing)

Time display (12 hour or 24 hour

Days of the week (the square indicates the current day)

Temperature display

Temperature sensor malfunction

Increase the setting or change the selection

Decrease the setting or change the selection

Choose menu and selection

Exit the setting menu or go into standby mode

+

+

This screen is shown during 

registration. 

The        symbol will flash. When 

registration is complete, the startup

screen appears.

This screen appears when the 

remote control is not registered. The        

symbol          will flash. Switch on 

the fireplace within 5 minutes and 

register as follows: press the     and      

buttons simultaneously

2. MAINTENANCE AND USE INSTRUCTIONS

Summary of Contents for EVA992GAZ

Page 1: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 2: ......

Page 3: ...ufficient load bearing capacity If an existing building does not meet this prerequisite adequate measures e g installation of a load distribution plate must be taken to enable the floor to support the...

Page 4: ...0 0 120 0 120 Burner pressure mbar 28 3 28 3 28 3 28 3 Burner injector 2x 120 100 COMMON CHARACTERISTICS Concentric system C11 130 200 C31 C91 100 150 Configuration C11 C31 C91 Minimum distance betwee...

Page 5: ...AL CHARACTERISTICS OF THE WALL MOUNTED APPLIANCE 816mm 1175mm 600mm 460mm 370mm 1680mm Adaptable ceiling height 820mm ACCESS HATCH Must remain accessible BASE Metal Brick Ceramic FIREPLACE Natural Gas...

Page 6: ...technical point of view based on the tables of paragraph How to calculate the deflector position If it is not an alternative layout must be determined Attention depending on the layout the appliance...

Page 7: ...he outside of the concentric system and combustible materials is 50mm The flue ducts must slide into each other correctly and form a stable whole Airtightness must be achieved according to POUJOULAT s...

Page 8: ...ign office must be respected in order to comply with the assembly and installation configuration The hood is to be positioned and fixed using the 3 brackets already installed on the fireplace Brackets...

Page 9: ...removing the 2 screws from each bracket retracting the bracket on the deflector to put it in the correct position and tightening the screws once more Do this on each bracket individually to make it ea...

Page 10: ...burner pressure must be checked during commissioning Please refer to the technical characteristics provided at the beginning of these instructions Warning This appliance is pre set and sealed at the...

Page 11: ...INSTALLATION OF THE APPLIANCE 1 INSTALLATION INSTRUCTIONS...

Page 12: ...operation and can change the flame appearance The appliance finishing paint is a special paint With high temperature strength that finishes hardening during the first ignitions It is very important no...

Page 13: ...o the plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas...

Page 14: ......

Page 15: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 16: ...or sparks open windows and doors close the gas supply tap and contact your installer Never use a flame to check for gas leaks Any operation inside the appliance must be performed by a qualified profe...

Page 17: ...of minutes This step is called bnd USING THE REMOTE CONTROL USING THE REMOTE CONTROL The remote control has been specifically designed to work with the gas inflow control system in your appliance It...

Page 18: ...24 heures USING THE REMOTE CONTROL The remote control has a screen and four buttons It provides easy control of the fireplace The settings can also be easily changed There are two adjustment menus Us...

Page 19: ...ary change is automatically cancelled Temporary stoppage of the program When using the programmer you can also temporarily turn off the fireplace Press the button when the fireplace is lit N B the des...

Page 20: ...button to exit the menu INSTALLATION MENU To select the Installation menu follow these steps Close the User menu if it is open Then hold down the button for 10 seconds The Installation menu lets you...

Page 21: ...alternately If a program has been selected the screen displays the status of the situation Malfunction of the temperature sensors of the remote control and the fireplace or sensor in the latter unava...

Page 22: ...he plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas ta...