INSTALLATION OF THE APPLIANCE

INSTALLATION OF THE BASE PLATES

The base plates are to be attached using the bolts provided.

The counter-sinks should be upwards to accept the heads.

INSTALLATION OF THE HOOD AND FLUES

Before installing the hood and flues, make sure the hood 

mounting brackets are in place. Otherwise, install them.

Depending on the configuration, the diameter of the flue 

ducts will be different, but the nozzle is identical: 

Ø130/200

Flue ducts compatible with your appliance are 

POUJOULAT 

DUOGAS

ducts.

Warning: No other flue duct can be used.

Terminal references and specific material:
C11 Configuration

Ø130/200 (horizontal outlet)

Mandatory nozzle adapter: 

A130/200SEGDG

Mandatory horizontal terminal: 

STHR G 130 DG

C31 Configuration

Ø100/150 (vertical outlet)

Mandatory nozzle adapter: 

A130/200SEGDG

Mandatory reduction: 

RC100/150-130/200DG

Mandatory vertical terminal: 

CTIV G 100 DG

Brackets

C91 Configuration 

Ø100/150

Mandatory nozzle adapter: 

A130/200SEGDG

Mandatory reduction: 

RC100/150-130/200DG

Mandatory vertical terminal: 

CTIV G 100 DG

Square ceiling starting kit:

KRFL C 100 DG

Rectangular ceiling starting kit:

KRFL R 100 DG

Square floor starting kit: 

KRFLC CCH 100 DG

Rectangular floor starting kit:

KRFLR CCH 100 DG

Flexible coating: 

STAR 100 2010

Insulated flexible flue duct:

LI 100 DP-U

For a C31 or C91 installation, an adapter 

(Ø130/200

Ø100/150) must be attached to the nozzle and 

Ø100/150 ducts used up to the roof outlet.

Warning: the reduction must be installed on the adaptor on 

the nozzle.

The smoke outlet section must be consistent and uniform 
throughout its length; no diameter change on the system is 
authorised. 

The minimum distance between the outside of the concentric 
system and combustible materials is 50mm.

The flue ducts must slide into each other correctly and form a 

stable whole.

Airtightness must be achieved according to POUJOULAT 
specifications. Any other complementary means is forbidden.
Vertical flue ducts must be installed with the female part 
looking up.
When the flue ducts pass through the roof, accessories 
recommended by the manufacturer must be used. 

Connection with the building
-Flues must neither be obstructed nor sealed when crossing 
the walls.
-Crossing of outside walls must be made inside sheaths.

-Ducts must neither be built-in, incorporated nor engraved in 
masonry.
-If fixing is needed, it must be done using clamps.

Pathway inside the building where the appliance has been 
placed.
-Flue ducts can pass through premises (or outbuildings) 
different from those where the appliance has been installed. 
In that case they must be placed inside a casing.
-These prescriptions do not apply to ducts crossing 
undeveloped attic spaces unless the flue surface temperature 
exceeds 80

°

C during normal operation.

-Safety clearance between the flue and combustible 

materials: please refer to manufacturer's prescriptions.

How to make the casing:
-It is necessary to comply with the safety clearances from 
combustible materials.
-The casing must be permanently ventilated by top and 

bottom openings, each with an area greater than or equal to 

20cm² and placed so as to include the whole annular space 

-Warning: if a wall-bushing insulated kit (insulating shell) is 

used, it is necessary to refer to the manufacturer’s 

specifications for information about the ventilation needed 
(this is much more important).
-If the casing is placed at a shorter distance than the safety 
clearance, then it must be made entirely of materials 
belonging to the M0, A2s1d0 or A1 reaction-to-fire class.

1. INSTALLATION INSTRUCTIONS

Summary of Contents for EVA992GAZ

Page 1: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 2: ......

Page 3: ...ufficient load bearing capacity If an existing building does not meet this prerequisite adequate measures e g installation of a load distribution plate must be taken to enable the floor to support the...

Page 4: ...0 0 120 0 120 Burner pressure mbar 28 3 28 3 28 3 28 3 Burner injector 2x 120 100 COMMON CHARACTERISTICS Concentric system C11 130 200 C31 C91 100 150 Configuration C11 C31 C91 Minimum distance betwee...

Page 5: ...AL CHARACTERISTICS OF THE WALL MOUNTED APPLIANCE 816mm 1175mm 600mm 460mm 370mm 1680mm Adaptable ceiling height 820mm ACCESS HATCH Must remain accessible BASE Metal Brick Ceramic FIREPLACE Natural Gas...

Page 6: ...technical point of view based on the tables of paragraph How to calculate the deflector position If it is not an alternative layout must be determined Attention depending on the layout the appliance...

Page 7: ...he outside of the concentric system and combustible materials is 50mm The flue ducts must slide into each other correctly and form a stable whole Airtightness must be achieved according to POUJOULAT s...

Page 8: ...ign office must be respected in order to comply with the assembly and installation configuration The hood is to be positioned and fixed using the 3 brackets already installed on the fireplace Brackets...

Page 9: ...removing the 2 screws from each bracket retracting the bracket on the deflector to put it in the correct position and tightening the screws once more Do this on each bracket individually to make it ea...

Page 10: ...burner pressure must be checked during commissioning Please refer to the technical characteristics provided at the beginning of these instructions Warning This appliance is pre set and sealed at the...

Page 11: ...INSTALLATION OF THE APPLIANCE 1 INSTALLATION INSTRUCTIONS...

Page 12: ...operation and can change the flame appearance The appliance finishing paint is a special paint With high temperature strength that finishes hardening during the first ignitions It is very important no...

Page 13: ...o the plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas...

Page 14: ......

Page 15: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 16: ...or sparks open windows and doors close the gas supply tap and contact your installer Never use a flame to check for gas leaks Any operation inside the appliance must be performed by a qualified profe...

Page 17: ...of minutes This step is called bnd USING THE REMOTE CONTROL USING THE REMOTE CONTROL The remote control has been specifically designed to work with the gas inflow control system in your appliance It...

Page 18: ...24 heures USING THE REMOTE CONTROL The remote control has a screen and four buttons It provides easy control of the fireplace The settings can also be easily changed There are two adjustment menus Us...

Page 19: ...ary change is automatically cancelled Temporary stoppage of the program When using the programmer you can also temporarily turn off the fireplace Press the button when the fireplace is lit N B the des...

Page 20: ...button to exit the menu INSTALLATION MENU To select the Installation menu follow these steps Close the User menu if it is open Then hold down the button for 10 seconds The Installation menu lets you...

Page 21: ...alternately If a program has been selected the screen displays the status of the situation Malfunction of the temperature sensors of the remote control and the fireplace or sensor in the latter unava...

Page 22: ...he plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas ta...

Page 23: ...aler an installer or a user This warranty shall not cover appliances not repaired by duly trained specialists authorised by BORDELET Damage occurring during transport is not covered by this warranty b...

Page 24: ......

Page 25: ...Nameplate of your appliance...

Page 26: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...

Reviews: