INSTALLATION OF THE APPLIANCE
INSTALLATION OF THE BASE PLATES
The base plates are to be attached using the bolts provided.
The counter-sinks should be upwards to accept the heads.
INSTALLATION OF THE HOOD AND FLUES
Before installing the hood and flues, make sure the hood
mounting brackets are in place. Otherwise, install them.
Depending on the configuration, the diameter of the flue
ducts will be different, but the nozzle is identical:
Ø130/200
Flue ducts compatible with your appliance are
POUJOULAT
DUOGAS
ducts.
Warning: No other flue duct can be used.
Terminal references and specific material:
C11 Configuration
=
Ø130/200 (horizontal outlet)
Mandatory nozzle adapter:
A130/200SEGDG
Mandatory horizontal terminal:
STHR G 130 DG
C31 Configuration
=
Ø100/150 (vertical outlet)
Mandatory nozzle adapter:
A130/200SEGDG
Mandatory reduction:
RC100/150-130/200DG
Mandatory vertical terminal:
CTIV G 100 DG
Brackets
C91 Configuration
=
Ø100/150
Mandatory nozzle adapter:
A130/200SEGDG
Mandatory reduction:
RC100/150-130/200DG
Mandatory vertical terminal:
CTIV G 100 DG
Square ceiling starting kit:
KRFL C 100 DG
Rectangular ceiling starting kit:
KRFL R 100 DG
Square floor starting kit:
KRFLC CCH 100 DG
Rectangular floor starting kit:
KRFLR CCH 100 DG
Flexible coating:
STAR 100 2010
Insulated flexible flue duct:
LI 100 DP-U
For a C31 or C91 installation, an adapter
(Ø130/200
→
Ø100/150) must be attached to the nozzle and
Ø100/150 ducts used up to the roof outlet.
Warning: the reduction must be installed on the adaptor on
the nozzle.
The smoke outlet section must be consistent and uniform
throughout its length; no diameter change on the system is
authorised.
The minimum distance between the outside of the concentric
system and combustible materials is 50mm.
The flue ducts must slide into each other correctly and form a
stable whole.
Airtightness must be achieved according to POUJOULAT
specifications. Any other complementary means is forbidden.
Vertical flue ducts must be installed with the female part
looking up.
When the flue ducts pass through the roof, accessories
recommended by the manufacturer must be used.
Connection with the building
-Flues must neither be obstructed nor sealed when crossing
the walls.
-Crossing of outside walls must be made inside sheaths.
-Ducts must neither be built-in, incorporated nor engraved in
masonry.
-If fixing is needed, it must be done using clamps.
Pathway inside the building where the appliance has been
placed.
-Flue ducts can pass through premises (or outbuildings)
different from those where the appliance has been installed.
In that case they must be placed inside a casing.
-These prescriptions do not apply to ducts crossing
undeveloped attic spaces unless the flue surface temperature
exceeds 80
°
C during normal operation.
-Safety clearance between the flue and combustible
materials: please refer to manufacturer's prescriptions.
How to make the casing:
-It is necessary to comply with the safety clearances from
combustible materials.
-The casing must be permanently ventilated by top and
bottom openings, each with an area greater than or equal to
20cm² and placed so as to include the whole annular space
-Warning: if a wall-bushing insulated kit (insulating shell) is
used, it is necessary to refer to the manufacturer’s
specifications for information about the ventilation needed
(this is much more important).
-If the casing is placed at a shorter distance than the safety
clearance, then it must be made entirely of materials
belonging to the M0, A2s1d0 or A1 reaction-to-fire class.
1. INSTALLATION INSTRUCTIONS
Summary of Contents for EVA992GAZ
Page 1: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...
Page 2: ......
Page 11: ...INSTALLATION OF THE APPLIANCE 1 INSTALLATION INSTRUCTIONS...
Page 14: ......
Page 15: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...
Page 24: ......
Page 25: ...Nameplate of your appliance...
Page 26: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...