background image

Adjusting the flame height

Press the

or

button once. The screen below will

appear.

Wait a few seconds or press the

button to exit the menu.

Turning off the fireplace

Press the

button to turn off the fireplace.

Adjusting the temperature

The fireplace turns on and off automatically based on heating

requirements. Press the

and

buttons to select the

desired temperature. The screen shown below will appear.

Wait a few seconds or press the

button to exit the menu.

Temporary bypass of the temperature setting

The temperature adjustment function also lets you

temporarily turn off the fireplace.

Press the

button to turn off the fireplace.

N.B.: the temperature cannot be changed when the

temperature setting function is bypassed.

The current temperature flashes. Select 

the desired temperature using the     

and     buttons. Depending on the 

button used, the symbols      or    

appear on the screen. The temperature 

can be set to a value between 5.0 and 

35.0 ° C

The symbol               flashes, indicating 

that the hotplate must be turned on 

manually by simultaneously pressing the 

and      buttons.

As soon as the fireplace is turned on 

again, the temperature adjustment 

function is reactivated.

If the fireplace, the receiver or the remote control are

replaced, the remote control must be registered manually,

see

Procedure for remote control recognition.

Setting the day and time

Le programmateur de la télécommande est disponible

uniquement si

l’heure

est réglée. Le réglage du jour et de

l’heure s’effectue

à partir du menu

Utilisateur , voir Réglage

du jour et de

l’heure

Vous pouvez régler l'affichage du temps, sur 12 ou 24 heures,

à partir du menu

Installation, voir Affichage sur 12 ou 24

heures.

USING THE REMOTE CONTROL

The remote control has a screen and four buttons. It provides

easy control of the fireplace. The settings can also be easily

changed.

There are two adjustment menus:

-

Use menu

-

Installation menu

Press the

menu

button

to select the User menu or press

and hold the

menu

button

for ten seconds to select the

Installation menu

Manual operation

Depending on the settings selected in the User menu, the

temperature or flame height can be set manually.

Adjusting the flame height

The fireplace is lit and turned off manually

Lighting the fireplace

*Depending on your

fireplace’s

factory settings, the

menu

button may not react with a single press, but must be held

down for 2 seconds.

The operational self-checking procedure is symbolized by the

hourglass

. The temperature displayed is that measured

by the probe in the remote control.

If the flame does not light or is not detected, the flame

symbol

will flash. To reset the box, press the

stop

button

Simultaneously press the      and     

buttons when the screen opposite 

appears.

The screen shown opposite will appear.

The      and      symbols flash, indicating

that the fireplace has been turned on.

As soon as the fireplace is lit, the screen 

shown below appears.

You can now manually adjust the flame 

height.

The flame height setting will flash. 

Adjust the desired height using the    

and     buttons. 

Depending on the button pressed, the      

or      symbol will be displayed.

The flame height is set on a scale from 

1 to 15

The screen opposite will appear. The     

symbol will flash, indicating that the 

fireplace has been turned off. Once it is 

turned off, the startup screen appears 

again.

The screen shown opposite will appear. 

The      symbol will flash, indicating that 

the fireplace has been turned off. Once 

it is off, the screen shown below 

appears.

USING THE REMOTE CONTROL

2. MAINTENANCE AND USE INSTRUCTIONS

Summary of Contents for EVA992GAZ

Page 1: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 2: ......

Page 3: ...ufficient load bearing capacity If an existing building does not meet this prerequisite adequate measures e g installation of a load distribution plate must be taken to enable the floor to support the...

Page 4: ...0 0 120 0 120 Burner pressure mbar 28 3 28 3 28 3 28 3 Burner injector 2x 120 100 COMMON CHARACTERISTICS Concentric system C11 130 200 C31 C91 100 150 Configuration C11 C31 C91 Minimum distance betwee...

Page 5: ...AL CHARACTERISTICS OF THE WALL MOUNTED APPLIANCE 816mm 1175mm 600mm 460mm 370mm 1680mm Adaptable ceiling height 820mm ACCESS HATCH Must remain accessible BASE Metal Brick Ceramic FIREPLACE Natural Gas...

Page 6: ...technical point of view based on the tables of paragraph How to calculate the deflector position If it is not an alternative layout must be determined Attention depending on the layout the appliance...

Page 7: ...he outside of the concentric system and combustible materials is 50mm The flue ducts must slide into each other correctly and form a stable whole Airtightness must be achieved according to POUJOULAT s...

Page 8: ...ign office must be respected in order to comply with the assembly and installation configuration The hood is to be positioned and fixed using the 3 brackets already installed on the fireplace Brackets...

Page 9: ...removing the 2 screws from each bracket retracting the bracket on the deflector to put it in the correct position and tightening the screws once more Do this on each bracket individually to make it ea...

Page 10: ...burner pressure must be checked during commissioning Please refer to the technical characteristics provided at the beginning of these instructions Warning This appliance is pre set and sealed at the...

Page 11: ...INSTALLATION OF THE APPLIANCE 1 INSTALLATION INSTRUCTIONS...

Page 12: ...operation and can change the flame appearance The appliance finishing paint is a special paint With high temperature strength that finishes hardening during the first ignitions It is very important no...

Page 13: ...o the plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas...

Page 14: ......

Page 15: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 16: ...or sparks open windows and doors close the gas supply tap and contact your installer Never use a flame to check for gas leaks Any operation inside the appliance must be performed by a qualified profe...

Page 17: ...of minutes This step is called bnd USING THE REMOTE CONTROL USING THE REMOTE CONTROL The remote control has been specifically designed to work with the gas inflow control system in your appliance It...

Page 18: ...24 heures USING THE REMOTE CONTROL The remote control has a screen and four buttons It provides easy control of the fireplace The settings can also be easily changed There are two adjustment menus Us...

Page 19: ...ary change is automatically cancelled Temporary stoppage of the program When using the programmer you can also temporarily turn off the fireplace Press the button when the fireplace is lit N B the des...

Page 20: ...button to exit the menu INSTALLATION MENU To select the Installation menu follow these steps Close the User menu if it is open Then hold down the button for 10 seconds The Installation menu lets you...

Page 21: ...alternately If a program has been selected the screen displays the status of the situation Malfunction of the temperature sensors of the remote control and the fireplace or sensor in the latter unava...

Page 22: ...he plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas ta...

Page 23: ...aler an installer or a user This warranty shall not cover appliances not repaired by duly trained specialists authorised by BORDELET Damage occurring during transport is not covered by this warranty b...

Page 24: ......

Page 25: ...Nameplate of your appliance...

Page 26: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...

Reviews: