SAFETY WARNINGS

Only a qualified installer should install the appliance. The 

appliance must be installed in accordance with the obligatorily 

instructions attached to the appliance, with the statutory 

texts and the applicable rules of the art, in particular:

-The February 23, 2018 decision (amended) relating to the 

technical and safety regulations applicable to gas and 

liquefied hydrocarbon installations located inside residential 

buildings or their outbuildings.

-The NF DTU 61.1 standard, P1 to P7 Gas installations in 

residential buildings 

-The NF DTU 24.2 standard on ventilation

-The Departmental Sanitary Regulations (RSD)

The gas appliances described in this manual are designed to

operate only in closed combustion chambers, i.e. with all the

glass screens and closing systems in place.

Before installation, check that the local distribution system

(identify the type of gas, the pressure and the appliance

settings) is compatible.

The appliance is configured and adjusted for certain types of

gases (natural gas G20-G25-G25.3, butane G30 or propane

G31) and these cannot be changed after delivery of the

appliance. The gas type is indicated on the rating plate.

These settings are factory-sealed, and no adjustment can be

made without BORDELET written authorisation

The gas valve has an ionization safety device which will off

the gas supply in the absence of a flame.

The combustion chamber is equipped with a valve to prevent

pressure increases. This valve is located above the fireplace.

Its freedom should be ensured after asssembly and before

starting the device.

In normal use this appliance is intended to operate under the 

following conditions;

- Maximum altitude: 1600 m

- Minimum and maximum storage temperatures: -20° C  

+65° C

- Minimum and maximum operating temperatures: 0° C  

+40° C

- Maximum indoor air humidity measured at 27° C DB (Dry 

Bulb) at 65% RH (Relative Humidity).

- Healthy indoor environment (devoid of corrosive 

substances)

- This appliance is intended to operate in Class II overvoltage 

and Level 2 pollution environments in accordance with 

IEC664. To maintain pollution level 2, you must protect it 

from splashes of water and oil and limit the amount of dust 

settling on it.

Never use a flame to check for gas leaks.

The appliance must be installed on a floor with sufficient 

load-bearing capacity. If an existing building does not meet 

this prerequisite, adequate measures (e.g. installation of a 

load distribution plate) must be taken to enable the floor to 

support the weight of the appliance.

All surfaces of the appliance are active surfaces and are 

therefore hot.

Floors, shelves and walls close to the appliance must be 

made from non-flammable materials.

IMPORTANT INFORMATION

INSPECTION ON ARRIVAL

Check the appliance immediately on arrival.

Make sure that the appliance is correct for the type of gas 

and the combustion product evacuation system as indicated 

on the nameplate of the appliance and on the gas settings 

label.

Notify the carrier and vendor if damage or defects are found.

All waste must be sorted and disposed of in suitable 

containers.

MAINTENANCE

The smoke outlet system must be cleaned at least once a 

year. Its airtightness must be checked. Disassembly of the 

deflector may be needed to perform these operations. We 

suggest that you take note of its position before removing it 

in order to be able to place it back in the same position.

We recommend having a specialist perform full maintenance

on the appliance once a year. Airtight seals as well as safety

and operation systems will need to be checked.

To ensure that your appliance is properly airtight, the seal 

around the glass must be replaced by a professional each 

year.

SPARE PARTS

Only use original spare parts to maintain the guarantee and 

correct operation of the appliance. 

You can buy spare parts from a specialized BORDELET or 

SEGUIN Group retailer.

RECYCLING

This home appliance is produced in compliance with

European Directive 2002/96/EC concerning the disposal of

Electrical and Electronic equipment.

This symbol indicates that the product may under no

circumstances be treated as household waste, it should be

taken to a special recycling centre for electrical and electronic

equipment.

Improper disposal of the appliance by the owner may be

subject to penalties under local legislation.

Selective sorting will assist with recycling and eco-friendly

processing at the end of its life and, this will help to prevent

negative impacts for the environment and health. It will

enable the materials comprising the appliance to be re-used

and/or recycled.

To find out more about your local waste recycling centres,

contact the waste recycling department in your area or ask in

the shop where you bought the appliance.

1. INSTALLATION INSTRUCTIONS

Summary of Contents for EVA992GAZ

Page 1: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 2: ......

Page 3: ...ufficient load bearing capacity If an existing building does not meet this prerequisite adequate measures e g installation of a load distribution plate must be taken to enable the floor to support the...

Page 4: ...0 0 120 0 120 Burner pressure mbar 28 3 28 3 28 3 28 3 Burner injector 2x 120 100 COMMON CHARACTERISTICS Concentric system C11 130 200 C31 C91 100 150 Configuration C11 C31 C91 Minimum distance betwee...

Page 5: ...AL CHARACTERISTICS OF THE WALL MOUNTED APPLIANCE 816mm 1175mm 600mm 460mm 370mm 1680mm Adaptable ceiling height 820mm ACCESS HATCH Must remain accessible BASE Metal Brick Ceramic FIREPLACE Natural Gas...

Page 6: ...technical point of view based on the tables of paragraph How to calculate the deflector position If it is not an alternative layout must be determined Attention depending on the layout the appliance...

Page 7: ...he outside of the concentric system and combustible materials is 50mm The flue ducts must slide into each other correctly and form a stable whole Airtightness must be achieved according to POUJOULAT s...

Page 8: ...ign office must be respected in order to comply with the assembly and installation configuration The hood is to be positioned and fixed using the 3 brackets already installed on the fireplace Brackets...

Page 9: ...removing the 2 screws from each bracket retracting the bracket on the deflector to put it in the correct position and tightening the screws once more Do this on each bracket individually to make it ea...

Page 10: ...burner pressure must be checked during commissioning Please refer to the technical characteristics provided at the beginning of these instructions Warning This appliance is pre set and sealed at the...

Page 11: ...INSTALLATION OF THE APPLIANCE 1 INSTALLATION INSTRUCTIONS...

Page 12: ...operation and can change the flame appearance The appliance finishing paint is a special paint With high temperature strength that finishes hardening during the first ignitions It is very important no...

Page 13: ...o the plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas...

Page 14: ......

Page 15: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 16: ...or sparks open windows and doors close the gas supply tap and contact your installer Never use a flame to check for gas leaks Any operation inside the appliance must be performed by a qualified profe...

Page 17: ...of minutes This step is called bnd USING THE REMOTE CONTROL USING THE REMOTE CONTROL The remote control has been specifically designed to work with the gas inflow control system in your appliance It...

Page 18: ...24 heures USING THE REMOTE CONTROL The remote control has a screen and four buttons It provides easy control of the fireplace The settings can also be easily changed There are two adjustment menus Us...

Page 19: ...ary change is automatically cancelled Temporary stoppage of the program When using the programmer you can also temporarily turn off the fireplace Press the button when the fireplace is lit N B the des...

Page 20: ...button to exit the menu INSTALLATION MENU To select the Installation menu follow these steps Close the User menu if it is open Then hold down the button for 10 seconds The Installation menu lets you...

Page 21: ...alternately If a program has been selected the screen displays the status of the situation Malfunction of the temperature sensors of the remote control and the fireplace or sensor in the latter unava...

Page 22: ...he plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas ta...

Page 23: ...aler an installer or a user This warranty shall not cover appliances not repaired by duly trained specialists authorised by BORDELET Damage occurring during transport is not covered by this warranty b...

Page 24: ......

Page 25: ...Nameplate of your appliance...

Page 26: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...

Reviews: