SAFETY WARNINGS
Only a qualified installer should install the appliance. The
appliance must be installed in accordance with the obligatorily
instructions attached to the appliance, with the statutory
texts and the applicable rules of the art, in particular:
-The February 23, 2018 decision (amended) relating to the
technical and safety regulations applicable to gas and
liquefied hydrocarbon installations located inside residential
buildings or their outbuildings.
-The NF DTU 61.1 standard, P1 to P7 Gas installations in
residential buildings
-The NF DTU 24.2 standard on ventilation
-The Departmental Sanitary Regulations (RSD)
The gas appliances described in this manual are designed to
operate only in closed combustion chambers, i.e. with all the
glass screens and closing systems in place.
Before installation, check that the local distribution system
(identify the type of gas, the pressure and the appliance
settings) is compatible.
The appliance is configured and adjusted for certain types of
gases (natural gas G20-G25-G25.3, butane G30 or propane
G31) and these cannot be changed after delivery of the
appliance. The gas type is indicated on the rating plate.
These settings are factory-sealed, and no adjustment can be
made without BORDELET written authorisation
The gas valve has an ionization safety device which will off
the gas supply in the absence of a flame.
The combustion chamber is equipped with a valve to prevent
pressure increases. This valve is located above the fireplace.
Its freedom should be ensured after asssembly and before
starting the device.
In normal use this appliance is intended to operate under the
following conditions;
- Maximum altitude: 1600 m
- Minimum and maximum storage temperatures: -20° C
+65° C
- Minimum and maximum operating temperatures: 0° C
+40° C
- Maximum indoor air humidity measured at 27° C DB (Dry
Bulb) at 65% RH (Relative Humidity).
- Healthy indoor environment (devoid of corrosive
substances)
- This appliance is intended to operate in Class II overvoltage
and Level 2 pollution environments in accordance with
IEC664. To maintain pollution level 2, you must protect it
from splashes of water and oil and limit the amount of dust
settling on it.
Never use a flame to check for gas leaks.
The appliance must be installed on a floor with sufficient
load-bearing capacity. If an existing building does not meet
this prerequisite, adequate measures (e.g. installation of a
load distribution plate) must be taken to enable the floor to
support the weight of the appliance.
All surfaces of the appliance are active surfaces and are
therefore hot.
Floors, shelves and walls close to the appliance must be
made from non-flammable materials.
IMPORTANT INFORMATION
INSPECTION ON ARRIVAL
Check the appliance immediately on arrival.
Make sure that the appliance is correct for the type of gas
and the combustion product evacuation system as indicated
on the nameplate of the appliance and on the gas settings
label.
Notify the carrier and vendor if damage or defects are found.
All waste must be sorted and disposed of in suitable
containers.
MAINTENANCE
The smoke outlet system must be cleaned at least once a
year. Its airtightness must be checked. Disassembly of the
deflector may be needed to perform these operations. We
suggest that you take note of its position before removing it
in order to be able to place it back in the same position.
We recommend having a specialist perform full maintenance
on the appliance once a year. Airtight seals as well as safety
and operation systems will need to be checked.
To ensure that your appliance is properly airtight, the seal
around the glass must be replaced by a professional each
year.
SPARE PARTS
Only use original spare parts to maintain the guarantee and
correct operation of the appliance.
You can buy spare parts from a specialized BORDELET or
SEGUIN Group retailer.
RECYCLING
This home appliance is produced in compliance with
European Directive 2002/96/EC concerning the disposal of
Electrical and Electronic equipment.
This symbol indicates that the product may under no
circumstances be treated as household waste, it should be
taken to a special recycling centre for electrical and electronic
equipment.
Improper disposal of the appliance by the owner may be
subject to penalties under local legislation.
Selective sorting will assist with recycling and eco-friendly
processing at the end of its life and, this will help to prevent
negative impacts for the environment and health. It will
enable the materials comprising the appliance to be re-used
and/or recycled.
To find out more about your local waste recycling centres,
contact the waste recycling department in your area or ask in
the shop where you bought the appliance.
1. INSTALLATION INSTRUCTIONS
Summary of Contents for EVA992GAZ
Page 1: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...
Page 2: ......
Page 11: ...INSTALLATION OF THE APPLIANCE 1 INSTALLATION INSTRUCTIONS...
Page 14: ......
Page 15: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...
Page 24: ......
Page 25: ...Nameplate of your appliance...
Page 26: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...