background image

INSTALLATION OF THE BASE

Place the base on a flat floor. The appliance has 4 height-

adjustable feet.

Please make sure to comply with distances from inflammable

materials as provided in the technical characteristics and

make sure that the appliance is in the correct position before

installing the base.

Caution, the foot screws will no longer be easily accessible

once the fireplace is mounted on the base.

A 10mm minimum distance between the base and the

floor must be kept to ventilate the appliance.

INSTALLING THE FIREPLACE ON THE BASE

Be careful not to damage the gas system mounted on the

base when installing the fireplace.

The fireplace must be oriented according to the 2 marks, one

on the base of the fireplace and one on the base plate.

Bolt the fireplace to the base using the 3 x 15mm-long M6

bolts.

Before continuing the installation, it is necessary to make 
sure that the pressure relief valve can move freely. 
In order to do so, lift it several times to the maximum from 
the outside of the fireplace. 

Warning: the data plate attached to the burner thermal shield 

with a small chain must remain accessible.

DETERMINING THE FLUE CONFIGURATION

Make a diagram of the desired layout of the concentric flue

system.

Respect the required distances from flammable materials and

the position of permitted outlets as described below when

positioning your appliance

Make sure the layout is permissible from a technical point of

view based on the tables of paragraph:

“How

to calculate the

deflector

position”

. If it is not, an alternative layout must be

determined.

Attention, depending on the layout, the appliance will use

either

POUJOULAT DUOGAS Ø130/200

flue ducts for C11

configuration, or

POUJOULAT DUOGAS Ø100/150

flue

ducts for C31 or C91 configuration.

PREPARATION OF THE GAS AND ELECTRICITY SUPPLY 

POINTS

The appliance may be connected to the gas and electricity

supplies inside the base, or outside for wall-mounted

appliances. When connecting inside the base, leave a certain

amount of space free. This is required to accommodate the

solenoid valve block, the flame controller and the receiver.

We recommend that you provide the gas supply and the

electrical connection on the front of the base. This will allow

easy access for any intervention subsequent to the

installation of the device.

REMOVING THE

FIREPLACE’S

GLASS SCREENS

Before commencing installation of the appliance, the

fireplace’s

glass screens must be removed.

To do this, remove the top and bottom fastenings and set

them aside for later.

Glass screens must be handled carefully using gloves.

The dismantled glass screens must be placed on a soft

surface away from people.

Even a small chip can quickly lead to a crack or even a

broken glass.

INSTALLATION OF THE APPLIANCE

Top fastenings

Glass screens to be removed

(x4) for free-standing appliance

(x3) for wall-mounted appliance

Bottom 

fastenings

Hearth mark

Base mark

Top view

435mm

1

7

0

m

m

Free space

Solenoid

Preferred

position of air 

inlets

Pressure release valve

Base hatch

1. INSTALLATION INSTRUCTIONS

Summary of Contents for EVA992GAZ

Page 1: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 2: ......

Page 3: ...ufficient load bearing capacity If an existing building does not meet this prerequisite adequate measures e g installation of a load distribution plate must be taken to enable the floor to support the...

Page 4: ...0 0 120 0 120 Burner pressure mbar 28 3 28 3 28 3 28 3 Burner injector 2x 120 100 COMMON CHARACTERISTICS Concentric system C11 130 200 C31 C91 100 150 Configuration C11 C31 C91 Minimum distance betwee...

Page 5: ...AL CHARACTERISTICS OF THE WALL MOUNTED APPLIANCE 816mm 1175mm 600mm 460mm 370mm 1680mm Adaptable ceiling height 820mm ACCESS HATCH Must remain accessible BASE Metal Brick Ceramic FIREPLACE Natural Gas...

Page 6: ...technical point of view based on the tables of paragraph How to calculate the deflector position If it is not an alternative layout must be determined Attention depending on the layout the appliance...

Page 7: ...he outside of the concentric system and combustible materials is 50mm The flue ducts must slide into each other correctly and form a stable whole Airtightness must be achieved according to POUJOULAT s...

Page 8: ...ign office must be respected in order to comply with the assembly and installation configuration The hood is to be positioned and fixed using the 3 brackets already installed on the fireplace Brackets...

Page 9: ...removing the 2 screws from each bracket retracting the bracket on the deflector to put it in the correct position and tightening the screws once more Do this on each bracket individually to make it ea...

Page 10: ...burner pressure must be checked during commissioning Please refer to the technical characteristics provided at the beginning of these instructions Warning This appliance is pre set and sealed at the...

Page 11: ...INSTALLATION OF THE APPLIANCE 1 INSTALLATION INSTRUCTIONS...

Page 12: ...operation and can change the flame appearance The appliance finishing paint is a special paint With high temperature strength that finishes hardening during the first ignitions It is very important no...

Page 13: ...o the plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas...

Page 14: ......

Page 15: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...

Page 16: ...or sparks open windows and doors close the gas supply tap and contact your installer Never use a flame to check for gas leaks Any operation inside the appliance must be performed by a qualified profe...

Page 17: ...of minutes This step is called bnd USING THE REMOTE CONTROL USING THE REMOTE CONTROL The remote control has been specifically designed to work with the gas inflow control system in your appliance It...

Page 18: ...24 heures USING THE REMOTE CONTROL The remote control has a screen and four buttons It provides easy control of the fireplace The settings can also be easily changed There are two adjustment menus Us...

Page 19: ...ary change is automatically cancelled Temporary stoppage of the program When using the programmer you can also temporarily turn off the fireplace Press the button when the fireplace is lit N B the des...

Page 20: ...button to exit the menu INSTALLATION MENU To select the Installation menu follow these steps Close the User menu if it is open Then hold down the button for 10 seconds The Installation menu lets you...

Page 21: ...alternately If a program has been selected the screen displays the status of the situation Malfunction of the temperature sensors of the remote control and the fireplace or sensor in the latter unava...

Page 22: ...he plan Check the gas supply pressure Adjust the gas pressure if needed Make sure there is no air in the circuit and purge the gas supply pipes if needed GAS SMELL There is a gas leak Close the gas ta...

Page 23: ...aler an installer or a user This warranty shall not cover appliances not repaired by duly trained specialists authorised by BORDELET Damage occurring during transport is not covered by this warranty b...

Page 24: ......

Page 25: ...Nameplate of your appliance...

Page 26: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...