NATURAL GAS - NG
Country
FR BE
DE LU PL RO
NL
DE
LV CY ES PT HU RO
GR HR EE FI IT LT CZ
GB SI SK AT DK IE
SE CH TR NO
Category
I2E+
I2E
I2EK
I2ELL
I2H
Gas type
G20/G25
G20
G25.3
G25
G20
Gas pressure
mbar
20/25mbar
20mbar
25mbar
20mbar
20mbar
Net heat output
kW
10,5
10,5
10,2
8,8
10,5
Nominal heating power
kW
8,2
8,2
8,0
6,6
8,2
Performance
%
78,5
78,5
77,9
76,3
78,5
Performance class
2
2
2
2
2
NOx (PCS)
mg/kWh
105,1
105,1
93,4
78,6
105,1
NOx class
4
4
4
5
4
Nominal gas consumption
m
3
/h
1,107
1,107
1,225
1,078
1,107
Minimum gas consumption
m
3
/h
0,412
0,412
0,446
0,412
0,412
Burner pressure
mbar
19,1
19,1
23,9
19,0
19,1
Burner injector
2x 195/100
TECHNICAL CHARACTERISTICS
BUTANE / PROPANE
Country
FR CY ES PT BE GR IT LT
CZ GB SI IE CH TR
HU RO HR EE FI DK NL
SE NO
DE LU AT CH
PL
Category
I3+
I3B/P
I3B/P
I3P
Gas type
G30/G31
G30/G31
G30/G31
G31
Gas pressure
mbar
(28-30)/37
30
50
37
Net heat output
kW
9,0
9,0
9,0
9,0
Nominal heating power
kW
7,0
7,0
7,0
7,0
Performance
%
77,7
77,7
77,7
77,7
Performance class
2
2
2
2
NOx (PCS)
mg/kWh
64,6
64,6
64,6
64,6
NOx class
5
5
5
5
Nominal gas consumption
m
3
/h
0,280
0,280
0,280
0,280
Minimum gas consumption
m
3
/h
0,120
0,120
0,120
0,120
Burner pressure
mbar
28,3
28,3
28,3
28,3
Burner injector
2x 120/100
COMMON CHARACTERISTICS
Concentric system
C11 = 130/200 | C31/C91=100/150
Configuration
C11/C31/C91
Minimum distance between the glass screens of the appliance and all combustible materials
1000mm
Type of backing wall material for wall-mounted appliances
Non-flammable materials*
Electrical characteristics (Voltage - Intensity - Frequence
–
Max Power)
AC: 230V
–
50Hz
–
2A
–
30Wmax
Weight of the standalone appliance (2.5m under ceiling)
205 kg
Weight of the wall-mounted appliance (2.5m under ceiling)
200 kg
*The backing wall must be made of non-combustible material and the whole surface of the construction right-of-way must be insulated. The
insulation must be in the M0, A2s1d0 or A1 reaction-to-fire class and must have a thermal resistance higher than 0.7m².K/W (measured at
50°C). The insulation must not deteriorate at temperatures below 400°C (e.g. calcium silicate, rock mineral wool, etc.).
If the backing wall is made of combustible material, it is necessary either:
- to remove the combustible material and to install insulation as described above;
- or to place a non-combustible partition at a distance of at least 2cm from the combustible material wall and to ventilate by two openings
(bottom and top). An insulation layer must then be placed on the partition as described above.
1. INSTALLATION INSTRUCTIONS
Summary of Contents for EVA992GAZ
Page 1: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...
Page 2: ......
Page 11: ...INSTALLATION OF THE APPLIANCE 1 INSTALLATION INSTRUCTIONS...
Page 14: ......
Page 15: ...Mod les MT190408GC MT190408GM JC BORDELET_ZI LHERAT _ 63310 RANDAN 202008_EN...
Page 24: ......
Page 25: ...Nameplate of your appliance...
Page 26: ...ZI de Lh rat 63310 RANDAN T l 0470561600 Fax 0470561689 www bordelet com...