background image

FRENCH

PG. 79

W415-2034 / A / 10.18.19

ADD MANUAL TITLE 

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030

Phone 1 (866) 820-8686 • www.napoleon.com • [email protected]

CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS: 

CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES

INSTALLER: 

Leave this manual with the appliance

CONSUMER: 

Retain this manual for future reference

ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)

NATURAL GAS MODELS:

PROPANE GAS MODELS:

Product Name / Code

(MUST use title from Price Book)

ADD ____ ILLUSTRATED

ADD PRODUCT IMAGE

CSA / 

INTERTEK

LOGO

SAFETY INFORMATION

- Do not store or use gasoline or other 
fl ammable vapors and liquids in the vicinity of 
this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

:

• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not 
use any phone in your building.

• 

Immediately call your gas supplier from a 
neighbour’s phone. Follow the gas    
supplier’s  instructions.

• 

If you cannot reach your gas supplier, call 
the fi re department.

- Installation and service must be 
performed by a qualifi ed installer, service 
agency, or the supplier.

This appliance may be installed in an aftermarket, 
permanently located, manufactured home (USA 
only) or mobile home, where not prohibited by 
local codes.

This appliance is only for use with the type of gas  
indicated on the rating plate. This appliance is 
not convertible for use with other gases, unless 
a certifi ed kit is used. 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 
could result in serious injury, death, or 
property damage.

WARNING

!

ENGLISH 

$10.00

FOR INDOOR USE ONLY

IF INSTAL OPERATION, ADD SERIAL 

NUMBER LABEL HERE

IF SEPARATE MANUALS, ADD “PLACE 

BARCODE LABEL ON THE OWNER’S MANUAL”

INSTALLATION MANUAL 

LV38N-1 / LV50N-2 / LV62N / LV74N / LV38N2-1 / LV50N2-2 / LV62N2 / LV74N2

LV38P-1 / LV50P-2 / LV62P / LV74P / LV38P2-1 / LV50P2-2 / LV62P2 / LV74P2 

Vector™ Series

(LV38-1 illustrated)

SAFETY BARRIER

THIS APPLIANCE IS SUITABLE FOR THE OPTIONAL DYNAMIC 

HEAT CONTROL™ SYSTEM

(See Dynamic Heat Control™ installation manual)

CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS: 

CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES

FOR INDOOR USE ONLY

H

HEAT CONT

T CONTROL

OL

TM

PATENT PENDING

PLACE BARCODE LABEL ON THE 

OWNER’S MANUAL

Summary of Contents for Vector Series

Page 1: ...partment Installation and service must be performed by a quali ed installer service agency or the supplier Thisappliancemaybeinstalledinanaftermarket permanently located manufactured home USA only or...

Page 2: ...burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children and...

Page 3: ...anemia those under the in uence of alcohol those at high altitudes are more affected by carbon monoxide than others Failure to keep the primary air opening s of the burner s clean may result in sooti...

Page 4: ...the battery holder switch for the rst time 38 6 6 access panel 39 6 7 wiring diagram 40 6 8 eFIRE application controller 40 6 8 1 LV38 1 LV50 2 wiring diagram 41 6 8 2 LV62 LV74 wiring diagram 42 7 0...

Page 5: ...on plated parts is best removed when the assembly is at room temperature but this can be improved if the assembly is warmed using a hair dryer or similar heat source The protective wrap must be remove...

Page 6: ...HR 21 000 22 000 21 000 22 000 Single Sided See thru Appliance Type LV50N 2 LV50P 2 LV50N2 2 LV50P2 2 Fuel Type Natural Gas Propane Natural Gas Propane Altitude FT 0 4 500 Max Input BTU HR 36 000 31...

Page 7: ...ppliance venting refer to venting installation section 7 Install vent shield refer to vent shield installation section 8 Install all electrical wirings refer to electrical information section 9 Instal...

Page 8: ...the unit is a direct vent sealed combustion product The installation must conform with local codes or in absence of local codes the National Gas and Propane Installation Code CSA B149 1 in Canada or t...

Page 9: ...e maison mobile si son installation conforme aux exigences de la norme CAN CSA Z240MH S ries de maisons mobile quip es au gaz en vigueur au Canada ou aux tats Unis selon la norme 24 CFR Part 3280 Manu...

Page 10: ...to secure the appliance to the oor for mobile home installation For mobile home installations the appliance must be secured This appliance is certi ed to be installed in an aftermarket permanently loc...

Page 11: ...269mm C 57 5 16 1456mm 69 5 16 1761mm 81 5 16 2065mm 93 5 16 2370mm 41 3 16 1046mm 7 1 16 179mm 18 5 8 473mm 3 1 8 80mm 19 7 8 1 2 12 7mm 505mm 32 3 4 832mm 39 11 16 1008mm 8 1 16 205mm 8 1 16 205mm 8...

Page 12: ...16 1761mm 81 5 16 2065mm 93 5 16 2370mm 2 2 see thru 41 3 16 1046mm 7 1 16 179mm 18 5 8 473mm 3 1 8 80mm 32 3 4 832mm 39 11 16 1008mm 16 3 16 411mm 8 1 16 205mm 8 1 16 205mm 8 203mm 5 127mm 1 2 12 7mm...

Page 13: ...n gurations allow several minutes 5 15 for the ame to stabilize after ignition Although not a requirement it is recommended for vent lengths that pass through unheated spaces attics garages crawl spac...

Page 14: ...erent venting manufacturer components must not be combined These vent kits allow for either horizontal or vertical venting of the appliance The maximum allowable horizontal run is 20 feet 6 1m The max...

Page 15: ...DED SINGLE SIDED SEE THRU SEE THRU 3 1 typical venting installation minimum plus rise maximum minimum base of air collar base of air collar D maximum special vent installation periscope termination Us...

Page 16: ...SEE THRU base of air collar A 6 1 83m minimum vertical rise is considered the minimum practical dimen sion for the speci c appliance enclosure and a minimal building structure However a greater minim...

Page 17: ...anda porch or deck N 16 40 6cm 16 40 6cm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without...

Page 18: ...lbow zone 1 3 elbow zone 1 4 elbow zone 1 5 elbow zone 1 6 elbow zone H V V H 40 ft For longer vent runs a power vent is required H 20 ft V H are measured from the centre of vent elbows Elbows are con...

Page 19: ...one 1 3 elbow zone 1 4 elbow zone 1 5 elbow zone 1 6 elbow zone H V V H 40 ft For longer vent runs a power vent is required H 20 ft V H are measured from the centre of vent elbows Elbows are considere...

Page 20: ...center of the vent elbows This example represents a vent that has a maximum of three 90 elbows a combined horizontal vent length H of 10 feet and a combined vertical vent length V of 8 feet 0 0 Base...

Page 21: ...0 ft V H are measured from the centre of vent elbows Elbows are considered as 90 Two 45 elbows One 90 elbow ALL APPLIANCES NATURAL GAS ONLY A 6 1 83m minimum vertical rise is considered the minimum pr...

Page 22: ...t H 10 ft For longer vent runs a power vent is required V H are measured from the centre of vent elbows Elbows are considered as 90 Two 45 elbows One 90 elbow For 0 elbow con gurations V is a minimum...

Page 23: ...a power vent is required V H are measured from the centre of vent elbows Elbows are considered as 90 Two 45 elbows One 90 elbow For 0 elbow con gurations V is a minimum of 6 to a maximum of 40 Vertic...

Page 24: ...V H 40 ft H 4 ft For longer vent runs a power vent is required V H are measured from the centre of vent elbows Elbows are considered as 90 Two 45 elbows One 90 elbow For 0 elbow con gurations V is a m...

Page 25: ...aterials consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof are suitable Materials that are reported as passing ASTM E136 standard test method for...

Page 26: ...cm min minimum framing Horizontal vent sections A minimum clearance of 3 76mm on the top outside of the enclosure and 2 51mm on the sides and bottom outside of the enclosure all around the vent pipe o...

Page 27: ...231 1cm minimum clearance The LV series requires a minimum enclosure ceiling height as illustrated dimension L measured from the bot tom of the appliance For temperature requirements this area must be...

Page 28: ...ature requirements this area must be left unobstructed Some venting con gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pip...

Page 29: ...stalled after framing Before framing a single sided appli ance ensure to install the restop rst L L minimum framing minimum framing Minimum enclosure ceil ing height may be higher depending on venting...

Page 30: ...o touch the vent pipe Remove insulation to allow for the installation of the attic shield and to maintain clearances to combustibles Do not ll the space between the vent pipe and enclosure with any ty...

Page 31: ...ether Figure 4 5 Ensure both ends line up and secure ends with clip and fasteners Figure 5 Fig 4 Fig 5 Fig 6 6 Insert the vent sleeve tabs into the restop spacer slots then bend the tabs over to secur...

Page 32: ...o cover up the open end of the shield and tighten This will prevent any materials such as insulation from lling up the 1 25mm air space around the pipe Caulking Vent Pipe Shield Vent Pipe Shield Vent...

Page 33: ...itional length needed for the nished wall surface Apply a heavy bead of the red RTV silicone W573 0002 not supplied to the inner sleeve of the air terminal Slip the vent pipe a minimum of 2 50 8mm ove...

Page 34: ...ealing with caulking Where possible cover the sides and top edges of the ashing with roo ng material F Aligning the seams of the terminal and air terminal connector place the terminal over the air ter...

Page 35: ...tical installations may display a very active ame If this appearance is not desirable the exhaust outlet may be restricted with a Wolf Steel approved restrictor kit This kit is not recommended for sho...

Page 36: ...the vent shield to its maximum vertical Figure 2 3 Use the fasteners in step 1 to hold the new vent shield height Figure 3 4 Unscrew the fasteners as shown Figure 4 DO NOT DISCARD FASTENERS 5 Use the...

Page 37: ...s If the battery holder switch is equipped with batteries the appliance will still have ON OFF functions during a power failure Refer to operation section in the Owner s manual when communications bet...

Page 38: ...attery holder note the polarity of the batteries and insert as indicated on the cover B Ensure the 3 position slider switch is switched to the REMOTE position middle position C Press the reset program...

Page 39: ...technician immediately to have the appliance inspected for damage to the electrical circuit Risk of electrical shock or explosion Do not wire 110V to the valve or to the appliance wall switch Incorrec...

Page 40: ...that ts your current mood or your d cor with ease the simple colour wheel tool swiftly scrolls through the full color spectrum Napoleon s eFIRE app controls every function of your replace including o...

Page 41: ...RECEIVER W660 0204 HIGH LIMIT SWITCH W750 0294 BLUETOOTH W190 0090 W190 0125 LED CONTROLLER COMMAND SENSE LED WIRE 8 LED WIRE MV TRANSFORMER W707 0019 LED LIGHTS W750 0358 LIGHT BLOWER PIGTAIL W707 00...

Page 42: ...0090 W190 0125 LED CONTROLLER COMMAND SENSE LED WIRE R LED WIRE L TRANSFORMER W707 0019 LED LIGHTS W750 0358 LIGHT BLOWER PIGTAIL W707 0027 ACCENT LIGHTS W750 0317 EXTENSION W750 0435 BT WIRE HARNESS...

Page 43: ...a quali ed installer Move the appliance into position and secure If equipped with a ex connector the appliance is designed to accept a 1 2 13mm gas supply Without the connector it is designed to accep...

Page 44: ...itch to the appliance J If the appliance will not operate follow instructions TO TURN OFF GAS and call your service technician or gas supplier A Set thermostat to lowest setting if equipped B Turn off...

Page 45: ...A timer will then begin the countdown for approximately seven days before shutting off the pilot if the appliance is not used This countdown will reset anytime the appliance main burner is used There...

Page 46: ...ill cause a re hazard note IMPORTANT 3 1 2 4 TOP VIEW Remove the screws from the appliance DO NOT DISCARD Align the nailing tab with the holes on the appliance secure with the screws in step 1 Secure...

Page 47: ...wall Insulation Ceiling Shaded components nish framing must be non combustible materials Finish framing must be built after the appliance has been placed in its nal position and venting connected note...

Page 48: ...ot need to be elevated above oor L 73 185 4cm 91 231 1cm M 3 76mm Insulation Drywall Can only be increased to 4 max by building a protrusion K E F J L M minimum framing This con guration also requires...

Page 49: ...1cm F 53 13 16 136 7cm 65 13 16 167 2cm 77 13 16 197 6cm 89 13 16 228 1cm J Optional Appliance does not need to be elevated above oor L 73 185 4cm 91 231 1cm K E F J L minimum framing note The LV seri...

Page 50: ...d bottom protrusions can be done with 4 10 1cm Max This is a recommended minimum dimension when mounting heat sensitive objects above the appliance see nishing and minimum combustible mantel clearance...

Page 51: ...ING Risk of re Never obstruct the front opening of the appliance The front of the appliance must be nished with any non combustible materials such as brick marble granite etc provided that these mater...

Page 52: ...139 1cm 66 3 4 169 5cm 78 3 4 200cm 90 3 4 230 5cm Non combustible nishing is required 7 17 9cm 15 5 8 39 7cm 18 1 2 47 1cm Q minimum non combustible SHADED AREA MUST BE NON COMBUSTIBLE MATERIALS Rece...

Page 53: ...the face of the safety barrier above the door and sides only If greater projections are needed increase the clearance to the sides and top by 2 51mm for every 1 25mm projection WARNING 4 10cm Maximum...

Page 54: ...r The 15 5 8 39 7cm above and the 7 178mm on either side of the appliance opening must not be nished with any combustible materials note No fasteners permitted with greater than 3 4 penetration into a...

Page 55: ...combustible mantel is considered a non combustible protrusion see nishing for protrusion restrictions Combustible mantel clearance can vary according to the mantel depth Use the graph to determine th...

Page 56: ...temperatures must be validated at the time of installation as air ow characteristics within the room can vary and maximum acceptable operating temperatures can vary from appliance to appliance TVs can...

Page 57: ...spring door latch mechanism WARNING Door trim Side view Door trim Door frame LV38 1 Illustrated A Remove the safety screen assembly refer to the safety screen installation removal section for details...

Page 58: ...he door to the appliance H Tilt the top of the door forward then lift it up and out of the bottom door retainer I When re installing the door life onto the bottom door retainer tilt the top towards th...

Page 59: ...rays Not only will this provide a clean look to the appliance but it also results in a most pleasing and clean burning ame Media trays should be stored in the event it is planned to install alternate...

Page 60: ...ishing It is recommended to only install media trays when using sand as media Media trays where supplied should be stored in the event it is planned to install alternate media at some point in the fut...

Page 61: ...closing the air shutter will cause a more yellow ame but can lead to carbonization Opening the air shutter will cause a more blue ame but can cause ame lifting from the burner ports The ame may not a...

Page 62: ...screw B Gauge should read as described on the chart below Check pressure with main burner operating on HI After taking pressure readings be sure to turn screws clockwise rmly to reseal Do not overtor...

Page 63: ...ner 5 If your appliance is equipped with a safety barrier cleaning may be necessary due to excessive lint dust from carpeting pets etc simply vacuum using the brush attachment 6 If your appliance is e...

Page 64: ...d replace as required If equipped with a blower access the blower and clean using a soft brush and vacuum Re assemble the various components in reverse order Inspect the relief system The appliance re...

Page 65: ...the media tray and burner assembly refer to the burner removal section for details 13 3 burner removal A Remove the safety screen and glass door refer to the safety barrier installation removal and do...

Page 66: ...gged into the control module It is critical that wire are reconnected to the appropriate connectors D Replace and reinstall components 13 5 control module removal CONTROL MODULE D Disconnect the ex co...

Page 67: ...er installation removal and door installation removal sections for details C Remove the media tray and burner assembly refer to the burner removal section for details D Unplug the LED strip from the c...

Page 68: ...ratch the glass surface thereby reducing its strength Do not operate the appliance with broken glass as leakage of ue gases may result Contact your local authorized dealer distributor for complete cle...

Page 69: ...rranty replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts always give the following information Model Serial Number of appliance...

Page 70: ...10 4090 SER Yes Access Door Assembly See thru W010 4198 SER W010 4162 SER W010 4202 SER W010 4090 SER Yes 4 Door Trim W715 1149 SER W715 1144 SER W715 1124 SER W715 1123 SER 5 Relief Door Assembly N A...

Page 71: ...EN W415 2034 A 10 18 19 71 replacement parts 14 2 burner components Items may not appear exactly as illustrated 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 19 20 21 22 23 25 26 27 28 29 18 17 15 24...

Page 72: ...0 0232 SER W100 0234 SER W100 0233 SER W100 0269 SER 11 Burner Ori ce NG W456 0038 W456 0034 W456 0031 W456 0030 Burner Ori ce P W456 0053 W456 0052 W456 0051 W456 0049 Yes 12 Media Tray Assembly W010...

Page 73: ...h a soap and water solution Air shutter improperly adjusted Return air shutter to speci ed opening see venturi adjustments section in the installation manual Carbon is being deposited on glass logs ro...

Page 74: ...eiver if equipped Reset program hold reset button on receiver and wait for 2 beeps Release after second beep Press small ame button on remote within 20 seconds you will hear an additional beep this si...

Page 75: ...layed on the transmitter LCD screen Step 2 Wait approximately 2 seconds and press the up arrow button the ignition sequence will start Starting from off press the on button on the transmitter After ap...

Page 76: ...caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to the appliance combustion chamber heat exchanger plated trim or other components due to water weather damage...

Page 77: ...EN W415 2034 A 10 18 19 77 17 0 notes...

Page 78: ...TI IN NG G O OV VE ER R 4 40 0 Y YE EA AR RS S A A A O O O O O OF F F F F F H H H H H H H HO O O O O OM M M M ME E E E E C C CO OM M MF F FO OR RT T P PR RO OD DU UC CT TS S 7200 Route Transcanadienne...

Page 79: ...ettent Cet appareil doit tre utilis uniquement avec le type de gaz indiqu sur la plaque d homologation Cet appareil ne peut tre converti d autres gaz sauf si une trousse de conversion est utilis e RIS...

Page 80: ...aux br lures accidentelles Une barri re de protection est recommand e si des individus risque se trouvent dans la maison A n de restreindre l acc s l appareil installez une barri re de protection ajus...

Page 81: ...eut entra ner la formation de suies et dommages la propri t Comme dans le cas de tout appareil combustion il est recommand de faire inspecter et entretenir votre appareil r guli rement De m me install...

Page 82: ...6 6 acc s aux contr les 113 6 7 sch ma de c blage 114 6 8 application contr leur eFIRE 114 6 8 1 LV38 LV50 2 sch ma de c blage 115 6 8 2 LV62 LV74 sch ma de c blage 116 7 0 branchement du gaz 117 8 0...

Page 83: ...batterie n cessite 4 piles AA L emballage de protection sur les pi ces plaqu es s enl ve mieux lorsque l assemblage est temp rature ambiante ou lorsqu il est chauff l aide d un s choir cheveux ou d u...

Page 84: ...1 000 22 000 21 000 22 000 Un Seul C t Voir Travers Type d appareil LV50N 2 LV50P 2 LV50N2 2 LV50P2 2 Type de Comburant Gaz Naturel Propane Gaz Naturel Propane Altitude PI 0 4 500 D bit max BTU h 36 0...

Page 85: ...ez vous la section Installation de ventilation 7 Installez le pare brise reportez vous la section installation du bouchon d vent 8 Installez tous les c blages lectriques reportez vous la section infor...

Page 86: ...ecteur de monoxyde de carbone est requis dans toutes les pi ces contenant des appareils aliment s au gaz L appareil n est pas approuv pour installation dans une chambre coucher ou une salle de bain mo...

Page 87: ...e chambre coucher une salle de bain et un studio Appropri pour installation dans une maison mobile si son installation conforme aux exigences de la norme CAN CSA Z240MH S ries de maisons mobile quip e...

Page 88: ...ons mobiles l appareil doit tre x en place Cet appareil est certi pour tre install dans une maison mobile install e de fa on permanente sauf si les codes locaux l interdisent Cet appareil ne doit tre...

Page 89: ...m 69 5 16 1761mm 81 5 16 2065mm 93 5 16 2370mm 41 3 16 1046mm 7 1 16 179mm 18 5 8 473mm 3 1 8 80mm 19 7 8 1 2 12 7mm 505mm 32 3 4 832mm 39 11 16 1008mm 8 1 16 205mm 8 1 16 205mm 8 203mm 5 127mm A B C...

Page 90: ...m 93 5 16 2370mm 2 2 voir travers 41 3 16 1046mm 7 1 16 179mm 18 5 8 473mm 3 1 8 80mm 32 3 4 832mm 39 11 16 1008mm 16 3 16 411mm 8 1 16 205mm 8 1 16 205mm 8 203mm 5 127mm 1 2 12 7mm 1 2 12 7mm A B C E...

Page 91: ...s le plancher ou le plafond sont travers s La terminaison du syst me d vacuation peut tre peints avec une peinture haute temp rature pour faire correspondre les couleurs ext rieures Utilisez une peint...

Page 92: ...t soit une vacuation verticale soit une vacuation horizontale de l appareil Lorsqu il utilise une terminaison horizontale la hauteur totale permise pour un vent veritcal est de 20 pieds 6 1m Lorsqu il...

Page 93: ...l 30 76 2cm min Base du collier d air 12 30 5cm minimum au niveau du sol D Base du collier d air LV38 1 LV50 2 30 76 2cm min installations particuli res d vents ensemble p riscopique Utilisez l ensemb...

Page 94: ...l vation verticale minimale de 6 1 83m tient compte des dimensions minimales pratiques pour l enceinte sp ci que de l appareil et d une structure mini male de construction Toutefois une l vation vert...

Page 95: ...s murs adjacents incluant les maisons voisines P 8 2 4m 8 2 4m Le toit doit tre incombustible et sans ouvertures Q 3 0 9m 3 0 9m Voir le tableau pour les dimensions d un mur plus large R 6 1 8m 6 1 8m...

Page 96: ...90 Two 45 elbows One 90 elbow 3 3 8 40 max LV38 1 see thru 3 3 terminaison horizontale gaz naturel Zone de coude Zone de coude Zone de coude Zone de coude Zone de coude Zone de coude LV38 1 LV50 2 LV6...

Page 97: ...Elbows are considered as 90 Two 45 elbows One 90 elbow 38 1 2 462 4 3 8 52 1 2 max LV62 see thru Zone de coude Zone de coude Zone de coude Zone de coude Zone de coude Zone de coude Base du collier d a...

Page 98: ...r collar Since the vent is located in the dark shaded area it is within the acceptable vent con guration 1 3 elb bo b w z w zo z ne n V V V2 2 2 H H H2 H H H1 4 3 4 57 1 3 Zone de coude Base du collie...

Page 99: ...air TOUS LES APPAREILS GAZ NATUREL SEULEMENT V H 40 ft Pour les courses d vacuation plus longues un vent de puissance est n cessaire H 20 ft V H sont mesur s partir du centre des coudes de ventilation...

Page 100: ...requis V H sont mesur s du centre partir du centre centre des coudes d vents Les coudes sont consid r s comme 90 Deux coudes de 45 Une coude de 90 Pour les con gurations avec z ro coude V est un mini...

Page 101: ...ngueurs un termi naison m canique est requis V H sont mesur s du centre partir du centre centre des coudes d vents Les coudes sont con sid r s comme 90 Deux coudes de 45 Une coude de 90 Pour les con g...

Page 102: ...ique est requis V H sont mesur s du centre partir du centre centre des coudes d vents Les coudes sont con sid r s comme 90 Deux coudes de 45 Une coude de 90 Pour les con gurations avec z ro coude V es...

Page 103: ...aux r pondant la norme ASTM E 136 m thode de test standard du comportement des mat riaux dans une fournaise avec tube vertical 1382 F 750 C et la norme UL763 sont consid r s comme tant des mat riaux n...

Page 104: ...horizontales Un d gagement minimum aux mat riaux combustibles de 3 76mm au dessus hors de l enceinte et 2 51mm sur les c t s at au dessous hors de l enceinte toute autour du conduit d vacuation sur t...

Page 105: ...s LV requis un minimum hauteur d enceinte plafond comme illustr dimension L mesur du bas de l appareil Pour les exigences de temp ratures cet espace doit tre d gager Certains con gurations qui requis...

Page 106: ...nceinte plus large pour fournir les d gagements minimaux entre les conduits d vacuation et les combustibles 1 25mm minimum tous les c t s pour les sections d vacuation verticale 2 51mm minimum tous le...

Page 107: ...4cm 91 231 1cm E J F E F J Avant d encadrer l appareil assurez vous d installer le socle avant qu il ne soit pas adapt entre les goujons si install apr s l encadrement Avant d encadrer l appareil assu...

Page 108: ...nstallation Risque d incendie vitez que l isolant touche au conduit d vacuation Retirez l isolant pour permettre l installation de l cran protecteur du grenier et pour maintenir les d gagements aux ma...

Page 109: ...urez vous que les deux extr mit s s alignent et xez les extr mit s avec des agrafes et des attaches Figure 5 6 Ins rez les languettes des douilles d vent dans les douilles d espaceur de feuillard plie...

Page 110: ...essoires dans le manuel du propri tairepour commander l ensemble sp ci que dont vous avez besoin A Une fois que vous aurez d termin l emplacement de la terminaison d coupez et charpentez une ouverture...

Page 111: ...rni Glissez la gaine exible sur le manchon int rieur de la terminaison en assurant un chevauchement minimal de 2 50 8mm et xez l aide d une minimum de trois vis B Installez la gaine exible ext rieure...

Page 112: ...necteur de terminaison gaines exibles travers le toit La terminaison doit tre verticale et d aplomb Fixez le connecteur de terminaison au support de toit en vous assurant que le dessus de la terminais...

Page 113: ...amme tr s active Si cette apparence n est pas d sir e la sortie du conduit d vacuation peut tre r duite en utilisant une plaque de restriction approuv e par Wolf Steel Cet ensemble n est pas recommand...

Page 114: ...3 4 D vissez les attaches comme indiqu sur la Figure 4 NE PAS D BRANCHER LES FIXATIONS 5 Utilisez les attaches l tape 4 pour xer le bouclier d vent sur l appareil Figure 5 6 Fixez le bouclier d vacuat...

Page 115: ...upteur de batterie et l metteur ont t perdues Le support inter rupteur de batterie met un son bip pour con rmer que la programmation a r ussi une fois que l alimentation a t restaur e Lors d une panne...

Page 116: ...es piles puis ins rez les comme indiqu sur le couvercle B Assurez vous que le commutateur glissi re est plac la position REMOTE position centrale C Appuyez sur le bouton r initialisation programmation...

Page 117: ...un technicien de service quali pour inspecter l appareil pour des dommages au circuit lectrique Risque de chocs lectriques ou d explosion Ne branchez pas le 110 V la soupape ou l interrupteur mural de...

Page 118: ...p napoleon com efire installez l application et profitez des fonctionnalit s propos es par l application eFIRE Controller Ne raccordez pas l interrupteur mural ou la soupape de gaz l alimentation lect...

Page 119: ...H W750 0294 BLUETOOTH W190 0090 W190 0125 LED CONTROLLER COMMAND SENSE LED WIRE 8 LED WIRE MV TRANSFORMER W707 0019 LED LIGHTS W750 0358 LIGHT BLOWER PIGTAIL W707 0019 W750 0429 W750 0423 ACCENT LIGHT...

Page 120: ...OMMAND SENSE LED WIRE R LED WIRE L TRANSFORMER W707 0019 LED LIGHTS W750 0358 LIGHT BLOWER PIGTAIL W707 0027 ACCENT LIGHTS W750 0317 EXTENSION W750 0435 BT WIRE HARNESS W750 0433 W750 0401 W405 0049 W...

Page 121: ...pas L installation et l entretien doivent tre effectu es par un installateur quali Mettez l appareil en place et xez le Si l appareil est muni d un raccord exible celui ci est con u pour recevoir une...

Page 122: ...entation de gaz et puis appelez votre technicien de service ou fournisseur de gaz A R gler le thermostat la r glage le plus bas si quip B Tournez l interrupteur murale de l appareil la position OFF C...

Page 123: ...use si l appareil n est pas utilis Ce d compte se r initialisera chaque fois que le br leur principal de l appareil sera allum Par cons quent si l appareil est utilis r guli rement sur une base journa...

Page 124: ...avec les deux vis d tape 1 UTILISEZ LES VIS FOURNIES POUR FINIR DE FIXER LES PATTES DE CLOUAGE SUR LE CADRE AVANT Pour installer les pattes de cloutahe pour les appareils de voir travers r p tez ces t...

Page 125: ...incombustibles Les composants ombrag s cadrage de nition doivent tre install s apr s que l appareil a t plac dans sa position nale et que l vacuation a t connect e note 10 0 encadrement ni apr s l in...

Page 126: ...composants ombrag s cadrage de nition doivent tre install s apr s que l appareil a t plac dans sa position nale et que l vacuation a t connect e note Plafond Isolation Cloison s che K E F J L M Cadrag...

Page 127: ...e des mat riaux incombustibles Les composants ombrag s cadrage de nition doivent tre install s apr s que l appareil a t plac dans sa position nale et que l vacuation a t connect e note Cloison s che I...

Page 128: ...inimaux de la tablette combustible particuli rement lorsque vous monter les objets lectronique Sinon il peut tre aussi minime que les permis de construction cadrage minimum Les composants ombr s encad...

Page 129: ...rent plus de 3 4 6 Risque d incendie N obstruez jamais l ouverture sur le devant de l appareil Si la nition de la fa ade de l appareil est fait elle doit tre faite de mat riau incombustible comme de l...

Page 130: ...at riaux incombustibles La nition incombustible est requis 7 17 9cm 15 5 8 39 7cm 18 1 2 47 1cm Q ECRAN DE PROTECTION LA ZONE NON SOMMAIRE DOIT TRE MAT RI AUX NON COMBUSTIBLES L installation en castr...

Page 131: ...face de la barri re de s curit au dessus de la porte et des c t s seulement Si des projections plus importantes sont n cessaires augmentez le d gagement sur les c t s et d passez 2 51mm pour chaque p...

Page 132: ...7 178mm de chaque c t de l ouverture de l appareil ne doivent pas tre nis avec des mati res combustibles note Nous vous recommandons d utiliser un adh sif haute temp rature et de serrer pour adh rer...

Page 133: ...dos le c t le haut l vent le manteau l avant etc sont clairement maintenus Lorsque vous utilisez de la peinture ou de la laque pour nir le manteau la peinture ou la laque doit tre r sistante la chaleu...

Page 134: ...jours aux exigences du fabricant du t l viseur Les temp ratures du t l viseur doivent tre valid es au moment de l installation car les caract ristiques de d bit d air dans la pi ce peuvent varier et l...

Page 135: ...e de la porte Ch ssis de la porte LV38 1 Illustr A Enlever la barri re de protection r f rer la section installation enl vement de la barri re de protection pour plus d information B Enlever la garnit...

Page 136: ...rte l appareil H Pivotez le haut de la porte vers l avant jusqu ce que vous puissiez saiser les c t s Soulevez la porte hors du support de porte inf rieur I Lorsque vous r installez la porte ins rez l...

Page 137: ...moins qu en utilisant le sable comme m dia il est recommand de N UTILISEZ PAS les plateaux m dia Cela assurera une apparence propre l appareil et aussi il en r sulte dans une amme tr s agr able et qui...

Page 138: ...de composants d coratif Nous recommandons d installer les plateaux de composants d coratifs seulement lors d installation du sable comme m dia Les plateaux si quip devraient tre stock e soigneusement...

Page 139: ...ferm le r glage du volet d air causera une amme plus jaune et aussi mener la carbonisation Si vous ouvrer le volet d air plus vela causera une amme plus bleu et aussi mener aux leverage de la amme des...

Page 140: ...ci dessous V ri er la pression avec le br leur principale sur HI Apr s avoir pris la lecture des pressions assurez vous de tourner fermement les vis vers la droite pour sceller Ne serrez pas trop fort...

Page 141: ...e br leur 5 Si votre appareil est fourni avec une cran de protection le nettoyage peut tre n cessaire en raison d un exc s de poussi re peluches des tapis animaux etc utilisez un l attachement du bros...

Page 142: ...ts d tanch it accessibles et remplacez les au besoin Acc dez la souf erie s il y a lieu puis nettoyez l aide d une brosse souple et d un aspirateur R installez tous les composants dans l ordre inverse...

Page 143: ...nt xer le plateau de composants d coratifs Soulevez l assemblage du br leur et retirez le hors de l appareil LV38 1 Illustr A Enlever l assemblage de l cran de protection et la porte r f rer au sectio...

Page 144: ...module de commande Il est essentiel que les ls soient reconnect s aux connecteurs appropri s D Remplacez et r installez les composants 13 5 enl vement du module de contr le CONTROL MODULE module de co...

Page 145: ...t installation enl vement de la porte vitr e pour plus de d tails C Retirez le plateau et l assemblage du br leur r f rer la section enl vement du br leur pour plus de d tails D D brancher la bande de...

Page 146: ...e du verre r duisant ainsi sa puissance Ne pas faire fonctionner l appareil avec la verre bris les fuites de gaz de combustion peut r sulter Contactez votre d taillant local autoris pour les instructi...

Page 147: ...nt de pi ce sous garantie une photocopie de la facture originale sera requise a n de pouvoir honorer la demande Lorsque vous commandez des pi ces donnez toujours l information suivante Mod le et num r...

Page 148: ...lage de la porte x e W010 4198 SER W010 4162 SER W010 4202 SER W010 4090 SER Yes Assemblage de la porte du c t d acc s Voir travers W010 4198 SER W010 4162 SER W010 4202 SER W010 4090 SER Yes 4 Garnit...

Page 149: ...W415 2034 A 10 18 19 145 pi ces de rechange FR 14 2 composants du br leur 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 19 20 21 22 23 25 26 27 28 29 18 17 15 24 Ces articles peut diff rer de celle illustr...

Page 150: ...0 0233 W100 0269 11 Injecteur du br leur NG W456 0038 W456 0034 W456 0031 W456 0030 Injecteur du br leur P W456 0053 W456 0052 W456 0051 W456 0049 Oui 12 Assemblage du plateau W010 4140 SER W010 4139...

Page 151: ...volet d air est r gl incorrectement Voir la section r glage du venturi pour le r glage de l ouverture du volet d air dans le manual d installation Du carbone se d pose sur la vitre les b ches les roc...

Page 152: ...ion de la veilleuse Le module n est pas mis la terre Assurez le bon polarit du thermocouple si fourni V ri ez si les assemblages de le veilleuse et de la soupape sont bien mis la terre R cepteur si qu...

Page 153: ...sur la che vers le haut la s quence d allumage se d clenchera En position off appuyez sur le bouton on de la t l commande Environ 4 secondes apr s que le bouton on off ait t enfonc le tableau d alluma...

Page 154: ...es d humidit la condensation des produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de Napol on Durant les dix premi res ann es Napol on remplacera ou r parera les pi...

Page 155: ...W415 2034 A 10 18 19 151 FR 17 0 notes...

Page 156: ...US S D DE E 4 40 0 A AN NS S D D E EXISTENCE C C C C C CO O O O O ON N N N N N N N NS S S S S SA A A A A AC C C CR R R R R S S L L LA A C CO ON NC CE EP PT TIO ON N D DE PR RODUITS DE CONFORT 7200 Rou...