Frame with addresses
- Write Maximum Work Temperature Command
Source Address: 00; original Target Address: 01; Command: W-MAT; set Max. Work Temp. to
375ºC
Communication Frame Examples for Soldering Stations
Codification
Start
Source
Address
Target
Address
Operation
Header
Operation
Code
Data
Stop
Check
ASCII
STX
00
01
W
MAT
00375
ETX
calculated
HEX
02
3030
3031
57
4D4154
3030333735
03
3E
Frame without addresses
- Write Maximum Work Temperature Command
Command: W-MAT; set Max. Work Temp. to 375 ºC / 707 ºF
Codification
Start
Operation
Header
Operation
Code
Data
Stop
Check
ASCII
STX
W
MAT
00375
ETX
calculated
HEX
02
57
4D4154
3030333735
03
3F
Sending code: 0230303031574D41543030333735033E
Sending code: 02574D41543030333735033F
Factory Settings for Control Box
Communication configuration:
19200 - 8N1
General Settings:
With Addresses:
Trarget Address: 01
Source Address: 00
Device
Port:
1
Mode/Status:
Extract
(stand
by)
Selected Work Temperature: 350 ºC / 662 ºF
Sleep Temperature: 150 ºC / 302 ºF
Sleep
Delay
Time:
10 sec.