R-TT
R-QTx
W-HAx
R-EDx
Read -
Transformer
Temperature
Read - Transistor
Temp. + port
Write - Higher
Temp
Alarm + port
Read - enter
delay time
(sleep/
hibernation)
+ port
To get the Power Supply Temperature.
The JBC device responds with an “A-TT”.
The Data Field contains the Transformer Temperature,
expressed in °C.
To get the current Transitor Temperature.
The ‘x’ must be replaced with the number of the
destination port in ACCII, for example “RQT1”.
The JBC device answers with an “A-QTx”.
The Data Field contains the current Transitor
Temperature, expressed in °C.
Sets the upper Temperature Alarm limit.
The ‘x’ must be replaced with the number of the
destination port in ASCII, for example, “WHA1”.
The data Field contains the upper Temperature Alarm
limit, epressed in °C. The temperature modification
must be done in steps of 5 degrees.
The JBC device responds with an “A-HAx”.
To get the remaining delay time before enter into sleep
or hibernation mode.
The ‘x’ must be replaced with the number of the
destination port in ACCII, for example “RED1”.
The JBC device answers with an “A-EDx”.
The Data Field contains the remaing time, expressed
in seconds.