R-PEx
R-SER
W-RST
Read - Port Error
+ port
Read - Station
Error
Write - Restart
Station
To get the Port Error.
See page 9 for value information.
The ‘x’ must be replaced with the number of the
destination port in ACCII, for example “RPE1”.
The JBC device answers with an “A-PEx”.
The Data Field contains the current Port Error. For
example “APE100004” for “no tool” error.
To get the JBC Device Error.
See page 9 for value information.
The JBC device responds with an “A-SER”.
The Data Field contains the JBC Device Error value.
To restart the JBC Device.
Code
Description
Details
R-CPx
Read - Counter
Plugged Hours
+ port
To get the Counter value for “Plugged Hours”,
Replace the ‘x’ with the number of the destination
port in ASCII, for example “RCP1”.
The JBC device responds with an “A-CPx”
The Data Field contains the Counter value of “Plugged
Hours”, expressed in hours.
W-RSP
Write - Reset
Station
Parameters
(factory default)
To reset the JBC Device Parameters to the factory
default parameters.
The JBC device responds with an “A-RSP”.
22