R-SMN
Read - Station
Model Name
To get the JBC Device Model Name
The JBC device responds with an “A-SMN”.
The Data Field contains the requested information.
Code
Description
Details
R-TAx
Read -
Temperature
Alarm + port
To get the Temperature Alarm indicator.
Replace the ‘x’ with the number of the destination
port in ASCII, for example “RTA1”.
The JBC device responds with an “A-TAx”.
The Data Field contains the Temperature Alarm value
according to:
0 - Alarm disabled
1 - Alarm activated
The units digit contains the high temperature alarm
(HTA) and the tens digit contains the low temperature
alarm (LTA).
Example:
00001 = HTA
00010 = LTA
00011 = HTA+LTA
‘0’ means there is no alarm.
‘1’ means the alarm has been previously set to “on”.
R-CTx
Read - Connect
Tool + port
To get the Connected Tool.
See page 8 for value information.
The ‘x’ must be replaced with the number of the
destination port in ACCII, for example “RCT1”.
The JBC device response with A-CTx.
The Data Field contains the identifier of the current
connected tool.