27
CONTROL PANEL
-
FUNCTIONS
Configuration Settings (Engineers mode)
Restore Factory Settings
To reset to factory settings for the EM
-
160C or the EM
-
200C, press
and hold the welding mode button
for 5 seconds to restore all
factory settings.
After holding the button for 1 second the display window will show
the start of a count down from 3 to zero.
When the countdown ends, the factory settings are restored.
If the button is released before the countdown ends, the restore will
not have taken place.
Factory settings are detailed and shown in the table below.
Welding
Process
Parameter
Restored Parameter
Value
EVO EM
-
160C
Restored Parameter
Value
EVO EM
-
200C
MIG
parameters
Burn back time
0.2S
0.2S
Burn back voltage
13V
13V
Inductance
0
0
Pre
-
flow time
0.1S
0.1S
Post
-
flow time
0.5S
0.5S
Welding voltage
19.0V
19.0V
Wire feeding speed
5m/min
5m/min
Crater voltage
19.0V
19.0V
Crater feeding speed
5m/min
5m/min
MMA
parameters
Arc
-
force current
40A
40A
Hot start current
30A
30A
Welding current
130A
130A
Lift TIG
parameters
TIG downslope time
0.5S
0.5S
Welding current
100A
100A
Summary of Contents for EVO 2.0 EM-160C
Page 1: ...1...
Page 75: ...75 UKCA Declaration of Conformity...
Page 76: ...76 EC DECLARATION OF CONFORMITY...
Page 78: ...78 SCHEMATIC...
Page 82: ...82...