20
CONTROL PANEL
-
FUNCTIONS
Digital Display
The top digital meter as shown below, is used to display many machine details including: current, wire
feeding speed, plate thickness parameters and error codes etc.
Below is listed some of the data that will be noted via this display.
•
When not welding, the preset current value will be displayed. If no operation is performed for set
period of time, the default parameters are displayed.
•
When welding, the actual output welding current value is displayed.
•
In MIG, this display will show wire feed speed in meters per minute (m/min).
•
In Synergic material thickness can be selected and displayed.
•
When the factory settings are restored, the countdown is displayed.
•
When the machines serial number is required, this display will show it.
•
When the product is not working correctly, an error code is will be shown on this display.
•
In welding engineer mode, the F
’0’
number will be shown on this display
•
Parameters are adjusted using the encoder dial shown in the image above
•
This control dial also always for access to the background settings
In MIG Synergic mode, MMA mode or Lift TIG mode, current is displayed by default. If Synergic is
disabled in MIG mode, the wire feed speed is displayed by default.
Top parameter adjustment knob and button
This multi functional control knob is used to scroll through the various parameters of the welding
equipment.
Depending on which welding process you have selected, by either pressing
or rotating the control knob this allows the operator to select the required
parameters of that welding process.
•
In MIG mode, if the "Synergic" function is disabled, the wire feed speed
can be set. If the function is enabled, rotate the knob to switch display
of current, wire feed speed and plate thickness for configuration.
•
In MMA or Lift TIG mode, the current parameter can be configured.
•
Rotate the adjustment knob to adjust the parameters.
•
Rotating the adjusting knob clockwise increases the parameter value, and rotating it counter
clockwise decreases the value.
•
When the adjustment knob is rotated, the adjusted parameter is displayed in the parameter display
area.
During welding, rotating the adjustment control knob will adjust the selected parameter and these
adjustments will also be noted by the array of green LED
’
s circling the control dial.
Summary of Contents for EVO 2.0 EM-160C
Page 1: ...1...
Page 75: ...75 UKCA Declaration of Conformity...
Page 76: ...76 EC DECLARATION OF CONFORMITY...
Page 78: ...78 SCHEMATIC...
Page 82: ...82...