![Jasic EVO 2.0 EM-160C Operator'S Manual Download Page 26](http://html1.mh-extra.com/html/jasic/evo-2-0-em-160c/evo-2-0-em-160c_operators-manual_3438750026.webp)
26
CONTROL PANEL
-
SETTINGS
Configuration Settings
Welding Engineers Mode functions (continued)
Please Note:
If entering the Welding Engineering Mode from different welding modes i.e. MIG or Tig for example, the
functional definition corresponding to the background parameters/functions may also differ!
For example:
If entering the Welding Engineering Mode background from the MIG welding mode, the pre
-
flow or
post
-
flow time set are the pre
-
flow/post
-
flow time of MIG mode.
Some models do not support F09, please confirm with the seller whether the machine supports wireless
remote control function first before purchasing.
Background
function
Parameter
no.
Default
value
Function definition
Post
-
flow time
F04
MIG: 0.5
Lift TIG: 5
Setting Port
-
flow time for either MIG or Lift TIG will depend
on which welding mode you are in when entering Welding
Engineer Mode.
If the "Welding Mode" is MIG, set the MIG post
-
flow time,
with range 0 ~ 5.0, accuracy of 0.5, and unit of seconds.
If the "Welding Mode" is Lift TIG, set the Lift TIG post
-
flow
time, with range 0 ~ 10, accuracy of 0.5, and unit of seconds.
Lift TIG
downslope
time
F05
0.5
Set the Lift TIG downslope time, with range 0 ~ 5,
adjustments in 0.5 seconds.
Burn back
Voltage
F06
13
Set the MIG burn back voltage, with range 10 ~ 20,
Adjustments in 0.1 volts.
Hot start
Current
F07
30
Set the MMA hot start current, with range 0 ~ 60,
adjustments of 1 and unit of amperes.
Initial wire
feed speed rate
F08
1
Setting the
‘
initial
’
wire feed speed rate of MIG wire which
can be set to either "0", "1", "2" or "3".
"0" indicates that the slow wire feed function is disabled.
"1", "2" or "3" indicate that the slow wire feed speed is 1/3,
1/2 or 2/3 of the current set speed, respectively.
Remote control
mode
F09
0
Can be set to "0" or "1" to use wireless or wired remote
controller.
"0" indicates wireless remote control mode.
"1" indicates wired remote control mode.