23
CONTROL PANEL
-
FUNCTIONS
Warning indicators
Over temperature
The overheat indicator light indicates that the machine has entered overheat protection and
has stopped welding output, the machine will re
-
activate once the unit has cooled down.
Do not turn off the machine when this indictor illuminates, wait for a while, and then continue
welding after the overheat indicator has turned off.
Over Current
The over
-
current indicator light indicates that the machine has entered over
-
current protection
and has stopped the output. Reset the machine by turning off and then back on.
If this error persists, please contact your supplier for further assistance.
Remote Control Switch
The remote selection control allows the user to select current control from either the
front panel or to be controlled remotely either via the 9 pin control socket or via the
optional wireless control. The LED indicator alongside the remote button indicates
whether remote control is enabled or not.
•
If the LED is OFF then current control is via the control panel and the panel adjustment dial will alter
the welding amperage
•
If the LED is ON then a connected wired or wireless hand/foot control will start the welding process
and control the amperage.
The remote control facility is effective for MIG, TIG and MMA operating.
Synergic Control Switch
This button allows the user to turn synergic mode ON or OFF.
With Synergic mode turned on means the machine will automatically match the welding
parameters according to the current, wire feed speed, material thickness with material
type, gas and wire diameter size.
On the EVO MIG machine, there are a multitude of pre
-
configured settings being changed by the
software to provide the best welding characteristics possible. The corresponding LED will light up to
indicate that you are in synergic mode.
Wire Inch Switch
When pressing and holding the wire inch button, the wire feed motor will run and feed
the welding wire through the drive system, into the MIG torch liner until it comes through
the welding tip. The corresponding LED will light up to indicate that you are feeding the
welding wire. Releasing the button will stop the wire feed.
Gas Purge Switch
This control button allows the operator to activate the shielding gas allowing for checking
and setting the gas flow. When the gas purge button is pressed, shielding gas will flow and
will continue to flow until the purge button is pressed again. The gas flow LED will be on
while the gas is flowing.
The operator can also deactivate gas flow by pushing the torch trigger or any other button on the control
panel while in gas purge check mode.
Note:
If the button is not pressed to exit the gas purging will exit automatically after 30 seconds.