Remove the battery from the holder using a small
insulated
screwdriver to push out the battery, direction
indicated by the two red arrows on Figure 8.2.4 and insert the new battery in the direction of the singe
green arrow on Figure 8.2.4.
Mount the control board on the interface board again by gently pressing the PCB to its rest on the
Interface Board. Make sure that all 4 corners are fully pressed towards the Interface Board.
Switch on the unit via the input switch Q1 and close the door. The unit now passes through the
initialization test and goes into standby mode.
Enter the setup menu and select menu item “Battery Replaced” to confirm new battery installation.
*
Important Note!
If the blue LED on the Control Board (location can be found on the Fig. 8.2.3) flashes with
approximate 2 flashes per second and the display reports “Communication Error”, the firmware
on the Control Board has been erased. The Control Board must be sent to ITW GSE to be
reloaded.
To ensure high reliability of the back-up battery, the only type of battery that can be used
on the Control Board is the Panasonic BR-2032