Operation Manual – ITW GSE 6400 Tier 3
d) Check
Radiator
Core
and
Hoses.
i.
Inspect the radiator core for dirt and debris blocking the fins. Clean as necessary.
Check for cracks, holes, or other damage.
ii. Check
Fuel
Pump.
iii.
Inspect the fuel injection pump mounting nuts for loose or damaged hardware.
2) Electrical (12 VDC system).
NOTE:
The battery furnished with this generator set is MAINTENANCE FREE.
a) Check
battery
terminals
and
clean
if
necessary.
3) Electrical (28.5 VDC System).
a) Check the operation of the E-F bypass system.
f) “C” Checks and Operations (500 Hours or 6 Months)
1) Engine.
a) Check Engine and Generator Mounts
CAUTION
An unstable or loosely mounted engine can create hazardous environment and may
damage equipment.
i.
Engine mount bolts must be torqued to 100 N-m (73.7 ft-lb.).
ii.
Generator mount bolts must be torqued to 100 N-m (73.7 ft-lb.).
b) Change
oil
and
oil
filters.
c) Change
all
fuel
filters.
d) Check
Coolant
Additive
Concentration.
The cooling system protective liquid (nitrite-, amine- and phosphate free) provides
effective protection against corrosion, cavitation, and freezing. See engine
manufacturer’s operation manual for ordering and mixture details.
2) Electrical (12 VDC system).
a) Wiring.
i)
Inspect all cables and leads for worn or damaged insulation.
b) Connections.
i)
Inspect connectors for damaged or corroded condition.
3) Electrical
(28.5
VDC
System).
a) Protective
Monitoring
Circuits.
Check operation of all protective monitoring circuits to make certain they will function if a
fault occurs in the output circuit. Procedures for testing these circuits are contained in the
Adjustment/Test section of this manual.
OM2254 Rev A
Page 60 of 103