User Guide
65
iii.
If these steps fail to remedy the situation the VersiCam camera maybe bad and needs to be sent in
for repair.
Symptom M: After a power cycle my system the time resets to 01-01-2000 and bin data is lost.
i.
The battery is dead or missing and needs to be replaced. The part number for the battery is CR2032.
Symptom N: I can connect to my system with VSU but it cannot identify my processors firmware version.
i.
Reinstall the newest VSU from the dealer web page for your particular processor. If you are installing
multiple VSU’s do the oldest first and the newest last. If you follow this procedure you will have the
most up to date history file.
ii.
Each time you run VSU it installs firmware for a particular processor. It is important to pick the
correct VSU version for you processor.
a.
08.01.17 is used on VersiCam.
Some people run into problems when the install the VSU for 04.01.17 and they try to connect to a
VersiCam system.
Symptom O: Bike Missed Calls
Bike Night Sensitivity
– Because of lighting conditions bicycles are harder to detect at night. Turning this
attribute on may help with missed calls in poor lighting conditions as it increases the sensitivity of the zone.
The proper solution is to improve the lighting at the intersection.
Bike Virtual Zone – If the camera is not mounted directly above the bike lane the Bike zone drawn may not be
rectangular but a parallelogram. Due to the position of the camera, the body of the bicycle rider may appear
out of the zone, and the call may be missed. This attribute will extend the zone in an attempt to capture the
rider. See figure below.
Bike Virtual Zone
On Screen Menu displaying Bike Zone Attributes
Note:
This attribute only works on zones at the stop bar. If you have a zone away from the stop bar,
then turning on this attribute will have no effect on performance.
Note:
The two attributes for Bike zones, both are set to off by default.
Summary of Contents for VersiCam
Page 1: ...Part Number 493432201 Rev F ...
Page 13: ...User Guide 13 2 1 Menu Tree ...
Page 30: ...User Guide 30 ...
Page 77: ...User Guide 77 10 TECHNICAL INFORMATION IMSA 39 2 40 2 Cable ...
Page 79: ...User Guide 79 VersiCam Specification Sheet ...
Page 80: ...User Guide 80 Phase Information ...
Page 81: ...User Guide 81 Detector Rack Configurations ...
Page 83: ...User Guide 83 ...
Page 84: ...1700 Carnegie Avenue Santa Ana CA 92705 Phone 949 270 9400 Fax 949 270 9401 ...