5.
OPERATION
5.1
Run Time Display
Note:
The following parameters are being used in VersiCam firmware version v08.01.17, the current
VersiCam firmware version at the time of this manuals publication. The following section is
somewhat firmware dependent and may change in future firmware versions. Always refer to the
current Vantage firmware release notes for the latest information on Vantage firmware features and
operation. The following information is a high level look at the Vantage firmware.
Zones Lighting with Detection
During operation when a vehicle is detected the outline of the zone will light up.
Constant Call
If the algorithm determines that a zone is not detecting it will go into failsafe mode. The output associated
with the zone will be turned on and a “@” symbol will be displayed above the zone. The system continues to
monitor conditions and if detection quality improves the system will exit this mode.
If the system determines that the whole image is a problem due to percentages from other cameras
being in LC or DID all detection outputs will be turned on. The system displays “GCC” on screen to
indicate that the system is in constant call due. GCC stands for Global Constant Call. This feature is
helpful when camera 1 has constant calls but is not in DID or LC and displays “GCC”. Then the user can
deduce that camera 2 is in DID or LC causing constant calls on camera 1.
Summary of Contents for VersiCam
Page 1: ...Part Number 493432201 Rev F ...
Page 13: ...User Guide 13 2 1 Menu Tree ...
Page 30: ...User Guide 30 ...
Page 77: ...User Guide 77 10 TECHNICAL INFORMATION IMSA 39 2 40 2 Cable ...
Page 79: ...User Guide 79 VersiCam Specification Sheet ...
Page 80: ...User Guide 80 Phase Information ...
Page 81: ...User Guide 81 Detector Rack Configurations ...
Page 83: ...User Guide 83 ...
Page 84: ...1700 Carnegie Avenue Santa Ana CA 92705 Phone 949 270 9400 Fax 949 270 9401 ...