ICC Module Wire Terminations
There are two sets of wire terminations that must be made on the ICC module. One multi-conductor
cable will be used for video, communication, and camera power. A second cable will be used for ICC
module power. Both cable terminations will be covered in detail in this section.
Installation of Grounding Lug
The following section covers installing the grounding lug on the cabinet side of the multi-conductor
cable.
3M Scotchlok 4460-D Grounding Lug
Take the three pair 19 AWG stranded multi-conductor cable and install the grounding lug per manufacturer’s
instructions. Carefully strip back the cable jacket sheath a total of about 2 ½ inches. Scoring the outer jacket
lightly with a sharp knife and bending the outer jacket sheath back and forth until it parts is the safest
method. Cut away the corrugated copper shield flush with the cable sheath being very careful not to nick the
twisted pair wires inside. Then cut back the cable core wrap (clear plastic) so about 3/4 of an inch remains as
shown in the picture below. Take a sharp knife or a pair of shears and carefully make a one inch slit in the
cable jacket sheath to ease insertion of the ground lug connector bottom.
Summary of Contents for VersiCam
Page 1: ...Part Number 493432201 Rev F ...
Page 13: ...User Guide 13 2 1 Menu Tree ...
Page 30: ...User Guide 30 ...
Page 77: ...User Guide 77 10 TECHNICAL INFORMATION IMSA 39 2 40 2 Cable ...
Page 79: ...User Guide 79 VersiCam Specification Sheet ...
Page 80: ...User Guide 80 Phase Information ...
Page 81: ...User Guide 81 Detector Rack Configurations ...
Page 83: ...User Guide 83 ...
Page 84: ...1700 Carnegie Avenue Santa Ana CA 92705 Phone 949 270 9400 Fax 949 270 9401 ...